EXIT the accumulation function
When the indicator show the last 4 digits, Press
hold it, the
indicator shows “clrn”, it means don’t clear the total Weight, Press
“PRINT” key to exit it; if you want to clear total weight, Press
“ZERO” or “TARE” key, “clrn” change to “clry” it means clear total
weight, then Press “PRINT” to clear the total weight and exit ac-
cumulating mode.
2.6 Print
2.7 Hold
2.8 COUNT
If the weighing is stable, aft er connected with printer press
”PRINT” can print the weight. Note: at tare mode, print with tare.
If negative weight, cannot print. Set C30 for time format.
Th
ere are two diff erent hold functions. Peak hold function
and data hold function the setting is diff erent accordingly.
C11=3 Automatic hold function
C11=0 close hold function.
1. At weighing mode, load the weights on the platform scales,
Press ”Count” the indicator show” PCS 0” press” Zero” key
input the quantity and press” Print” to confi rm it.
2. Load the goods on the platform scales and then the indicator
will show the quantity.
3. Press” Count” back to weighing mode.
4. If you want to weigh diff erent goods, at weighing mode, put
the sample on the platform scales, press” Count” the indicator
show ”0” Press “ Count” hold it and then press “ ON/OFF”
the indicator show” PCS 0”, press “Zero” input the sample
quantity, press “ Print” to confi rm it. Th
en repeat the step 2
and 3.
Содержание WS 10
Страница 1: ...WS 10 Weighing indicator USER MANUAL Edition 10052001A ...
Страница 5: ...1 3 Drawing ...