![Weidmüller Premium Line IE-SW-PL08M Series Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/weidmuller/premium-line-ie-sw-pl08m-series/premium-line-ie-sw-pl08m-series_hardware-installation-manual_952379013.webp)
- 13 -
MSTR/HEAD
GREEN
On
When the switch is set as the Master of
the Turbo Ring, or as the Head of the
Turbo Chain.
Blinking
The switch has become the Ring Master
of the Turbo Ring, or the Head of the
Turbo Chain, after the Turbo Ring or the
Turbo Chain is down.
Off
When the switch is not the Master of this
Turbo Ring or is set as the Member of the
Turbo Chain.
CPLR/TAIL
GREEN
On
When the switch coupling function is
enabled to form a back-up path, or when
it's set as the Tail of the Turbo Chain.
Blinking When the Turbo Chain is down.
Off
When the switch disables the coupling
function, or is set as the Member of the
Turbo Chain.
10M
(TP)
GREEN
On
TP port’s 10 Mbps link is active.
Blinking Data is being transmitted at 10 Mbps.
Off
TP Port’s 10 Mbps link is inactive.
100M
(TP)
GREEN
On
TP port’s 100 Mbps link is active.
Blinking Data is being transmitted at 100 Mbps.
Off
TP Port’s 100 Mbps link is inactive.
100M
(FX)
GREEN
On
FX port’s 100 Mbps is active.
Blinking Data is being transmitted at 100 Mbps.
Off
FX port’s 100 Mbps is inactive.
Auto MDI/MDI-X Connection
The Auto MDI/MDI-X function allows users to connect the10/100BaseTX ports
to any kind of Ethernet device, without needing to pay attention to the type of
Ethernet cable being used for the connection. This means that you can use either
a
straight-through cable or cross-over cable
to connect the IE-SW-PL08M
switches to Ethernet devices.
Fiber Ports
The fiber ports are factory-built as either multi-mode or single-mode SC/ST
connectors. Therefore, you should use fiber cables that have SC/ST connectors
at both ends. When plugging the connector into the port, make sure the slider
guide is positioned to the right side such that it fits snuggly into the port.