- 12 -
OFF: This
Ethernet Switch
will not be the
Ring Master.
OFF: Do not use
this Ethernet
Switch as the ring
coupler.
OFF: DIP
switches 1, 2, 3
will be disabled.
“Turbo Ring V2” DIP Switch Settings
DIP 1
DIP 2
DIP 3
DIP 4
ON: Enables the
default “Ring
Coupling
(backup)” port.
ON: Enables this
Ethernet Switch
as the Ring
Master.
ON: Enables the
default “Ring
Coupling” port.
ON: Activates
DIP switches 1, 2,
3 to configure
“Turbo Ring V2”
settings.
OFF: Enables the
default “Ring
Coupling
(primary)” port.
OFF: This
Ethernet Switch
will not be the
Ring Master.
OFF: Do not use
this Ethernet
Switch as a ring
coupler.
OFF: DIP
switches 1, 2, 3
will be disabled.
NOTE
You must enable the Turbo Ring function first before using the DIP
switch to active the Master and Coupler functions.
NOTE
If you do not enable any of the IE-SW-PL08M switches to be the
Ring Master, the Turbo Ring protocol will automatically choose the
switch with the smallest MAC address range to be the Ring Master.
If you accidentally enable more than one switch to be the Ring
Master, these switches will auto-negotiate to determine which one
will be the Ring Master.
LED Indicators
There are several LEDs on the Ethernet Switch front panel. The function of each
LED is described in the following table.
LED
Color
State
Description
PWR1
AMBER
On
Power is being supplied to power input
PWR1.
Off
Power is not being supplied to power
input PWR1.
PWR2
AMBER
On
Power is being supplied to power input
PWR2.
Off
Power is not being supplied to power
input PWR2.
FAULT
RED
On
When (1) a relay warning event is
triggered, (2) the switch is the Master of
this Turbo Ring, and the Turbo Ring is
broken, or (3) start-up failure.
Off
When a relay warning event is not
triggered.