background image

 

 

 

 

 

Hardware Installation Guide 

Gigabit Ethernet PoE Injector 

 

IE-INJ-EL02-2GTPoE (Part No. 2682440000) 

1.  Introduction 

This  PoE  injector  is  an  IEEE  802.3af/at  compliant  device  and  provides  2  independent 
10/100/1000Base-T(X)  PoE  output ports.  It  is designed  with  a  very  compact  and robust 
housing  to  be  used  in  harsh  industrial  environments.  To  ensure  reliable,  error-free 
operation,  and  to  prevent  damage  or  injury,  please  read  the  operating  instructions,  all 
safety information provided in this document  and  any  other safety information  that  were 
supplied with the product.  

2.  Safety notice 

 

Switch off the electrical power before removing the power connection! 

 

The device heats up during operation. Allow the unit to cool down or use 
protection gloves when carrying out any work. 

 

The device may only be connected to the supply voltage shown on the 
product label. Higher voltage than specified will destroy the device. 
The device must be supplied by a SELV source as defined in the Low 
Voltage Directive 2014/35/EU and 2014/30/EU. 

 

Installation, commissioning and maintenance may only be performed by 
qualified electricians. 

 

Observe the operating instructions. 

 

  Indoor use and pollution degree II, it must be wiped with a dry cloth for 

clean up the device and label. 

o

 Utilisation en intérieur et degré de pollution II, il faut l'essuyer avec un 

chiffon sec pour nettoyer l'appareil et son étiquette. 

  Do not block air ventilation holes. 

o

 Ne bouchez pas les orifices de ventilation. 

  If the equipment is used in a manner not specified by the manufacturer, 

the protection provided by the equipment may be impaired. 

o

 Si l’appareil est utilise d’une maniere non specifiee par le fabricant, la 

protection qu’il apporte peut se voir diminuee. 

  Shall be mounted in the Industrial Control Panel and ambient 

temperature is not exceed 75 degrees C. 

o

 Doit être monté dans le panneau de commande industriel et la 

température ambiante ne doit pas dépasser 75 degrés C. 

 
Intended use 

The  device  is  intended for  the  realization  of  communication  networks  within  an  industrial  environment,  it  is 
intended  to  be  used  in  a  restricted  access  location.  The  device  may  only  be  used  within  the  scope  of  the 
specified technical data. The device is intended to be mounted to a well-grounded mounting surface, such as 
a  metal  panel.  Any  other  use  may  result  in  unintentional  malfunction  and  damage.  Observing  the 
documentation is part of the intended use. 
 
Environmental conditions 
This equipment is intended to be used in a restricted access location. 
When planning the installation site make sure that the ambient temperature during operation will not exceed 
the temperature given in the technical data.  
Also make sure that the air flow will not be compromised by other devices. 
Ensure that the mounted and wired device is not exposed to any mechanical stress. 
 
FCC compliance 
This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2)  this  device  must  accept  any  interference  received, 
including interference that may cause undesired operation.

 

3.  Package Checklist 

Your Ethernet PoE Injector shipped with the following items:  
 

 

Gigabit Ethernet PoE Injector 

 

Hardware Installation Guide (printed) 

 

4-Pin Terminal connector 

 

Protective caps for RJ45 ports 

4.  Panel Layouts  

 

 

 

 

1.  Terminal block for power input (PWR) 

2.  Grounding screw / Frame ground 

 

(Note: The shielding ground of the LAN port 

is  electrically  connected  to  the  grounding 

screw) 

3.  Power Input LED (PWR) 

4.  10/100/1000Base-T(X) port (ETH 1 Data) 

5.  10/100/1000Base-T(X)  PoE  port  (ETH  1 

Data + PoE Out) 

6.  LED’s for PoE injection 

7.  10/100/1000Base-T(X) port (ETH 2 Data) 

8.  10/100/1000Base-T(X)  PoE  port  (ETH  2 

Data + PoE Out) 

9.  Article Number 

10.  DIN-Rail kit 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.  Mounting Dimensions 

 

 

 

 

 

 

 

(units = mm) 

 

6.  DIN-Rail Mounting 

Slide the PoE-Injector onto a DIN-rail and make sure that the device Din-rail clip clicks into 
the rail firmly. 
 

STEP 1

: Insert the top of the 

DIN-Rail into the slot just below 
the stiff metal spring. 

 

STEP 2:

 The DIN-Rail 

attachment unit will snap into 
place as shown below. 

 

To remove the DIN-rail from the PoE-Injector, simply reverse Steps 1 and 2. 

 

7.  Grounding the Ethernet PoE-Injector 

 

 ATTENTION 

-  Grounding and wire routing help limit the effects of noise due to 

electromagnetic interference (EMI).  

-   the ground connection from the ground screw to the grounding surface 

prior to connecting devices. 

-  This product is intended to be mounted to a well-grounded mounting 

surface, such as a metal panel. 

-  The shielding ground of the RJ45 ports are electrically connected to the 

ground connection (screw). 

 
 

Отзывы: