![Weidmuller UR20-4DI-4DO-PN-FSOE Скачать руководство пользователя страница 81](http://html.mh-extra.com/html/weidmuller-0/ur20-4di-4do-pn-fsoe/ur20-4di-4do-pn-fsoe_manual_952407081.webp)
7 Example applications
| Dual-channel two-hand monitoring with automatic start
81
u-remote IP20 modules for functional safety manual
1484600000/04/06.2017
Achievable safety rating
Category 4
EN ISO 13849-1
PLe
EN ISO 13849-1
SIL 3
EN 62061/61508
Stop category
0
EN 60204-1
Features
–
Dual-channel monitoring
–
Cross-connection detection
–
Automatic restart
–
Monitoring of external contactors
(EDM)
Safety sensor/operating
mechanism
Two-hand switch
Notes
The application must be compatible with
the automatic reset function.
All examples shown are proposals without
warranty. In any case the operator has to per-
form a safety review of the entire site.
1.1
1.2
1.3
1.4
3.1
3.2
3.3
3.4
4.1
4.2
4.3
4.4
1.1
1.2
1.3
1.4
2.1
2.2
2.3
2.4
2.1
2.2
2.3
2.4
3.1
3.2
3.3
3.4
4.1
4.2
4.3
4.4
UR20-PF-O-SIL UR20-4DO-P
K4
K3
S1
S2
Reset
L+(+24V)
M (0V)
M
K4
K3
Example application for dual-channel two-hand monitoring with automatic start
1)
Switchable modules see section 4.3
If one or both switches of the two-hand switch are released,
the PF-O-xDI-SIL switches off the 24 V supply for the
modules
1)
inside the safety segment and thus also for con-
tactors K3 and K4. The failure of a switching element in the
two-hand switch or a cross-circuit in its supply lines does not
result in the failure of the emergency stop mechanism and is
detected within the fault-reaction time. An interruption of the
NC contact by S2 is detected before the next switching cycle
and by S1 when the power is switched on.
The PF-O-xDI-SIL module switches on the 24 V supply
for the following modules
1)
within the safety segment if
–
the two-hand switch is pressed synchronously within
0,5 seconds
–
and the feedback circuit (NC contacts of K3 and K4) is
closed.
Contactors K3 and K4 are controlled by the PLC and can
switch on as soon as the PF-O-xDI-SIL has switched
on the 24 V supply. To reset the system,
press the reset but-
ton for 0.1 to 2 s after switching
on the power supply, even
when automatic reset is used.
7.7 Dual-channel two-hand monitoring with automatic start
Содержание UR20-4DI-4DO-PN-FSOE
Страница 1: ...Remote I O system u remote IP20 modules for functional safety Manual Original Letʼs connect ...
Страница 8: ...8 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 20: ...20 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 70: ...70 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 72: ...72 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 96: ...96 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 101: ...ANNEX A 5 1484600000 04 06 2017 u remote IP20 modules for functional safety manual EC Declaration of Conformity ...
Страница 102: ...ANNEX A 6 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 103: ...ANNEX A 7 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 104: ...ANNEX A 8 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 105: ...ANNEX A 9 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 106: ...ANNEX A 10 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 107: ...ANNEX A 11 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 108: ...ANNEX A 12 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 109: ...ANNEX A 13 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 110: ...ANNEX A 14 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 111: ...ANNEX A 15 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 112: ...ANNEX A 16 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 113: ...ANNEX A 17 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 114: ...ANNEX A 18 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 115: ...ANNEX A 19 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 116: ...ANNEX A 20 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 117: ...ANNEX A 21 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 118: ...ANNEX A 22 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 119: ...ANNEX A 23 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 120: ...ANNEX A 24 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 121: ...ANNEX A 25 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 122: ...ANNEX A 26 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Страница 124: ...A 28 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...