- 7 -
DIN-Rail Mounting
The aluminum DIN-rail attachment plate should already be fixed to the back
panel of the Ethernet Switch when you take it out of the box. If you need to
reattach the DIN-rail attachment plate, make sure the stiff metal spring is
situated towards the top, as shown in the figures below.
STEP 1
:
Insert the top of the DIN-Rail into
the slot just below the stiff metal
spring.
STEP 2
:
The DIN-Rail attachment unit will snap
into place as shown below.
To remove the Ethernet Switch from the DIN-Rail, simply reverse Steps 1 and 2
above.
ATEX Information
1.
Certificate number DEMKO 11
ATEX150193X
2.
Ambient range (-40
°
C ≤ Tamb ≤ 75
°
C)
3.
Certification string (Ex nA nL IIC T4)
4.
Standards covered (EN60079-0:2006, EN60079-15:2005)
5.
The conditions of safe usage:
The Ethernet Communication Devices are to be mounted in an IP54
enclosure and used in an area of not more than pollution degree 2 as
defined by IEC60664-1.
Use a conductor wire of size 0.2 mm or greater.
Conductors suitable for use in an ambient temperature of 100°C must be
used for the Power Supply Terminal.
Provisions shall be made, either in or external to the apparatus, to
prevent the rated voltage from being exceeded by more than 40% due to
transients disturbances.