Î
Lubricate the
contact surface of the
front seal (Pos. 7), at the
sleeve (Pos. 4) and at the
sealing disc (Pos. 5) with the
WEH
®
Lubricant
part No. E99-4.
Î
Lubricate the new front seal
(Pos. 7) with the
WEH
®
Lubricant
part No. E99-4.
Î
Insert the new
front seal (Pos. 7) into the
seal housing (Pos. 5) and let
it slide downwards against
the sleeve (Pos. 4).
Î
Screw the
connector housing (Pos. 1)
and the seal housing (Pos. 3)
back together.
Tightening torque
25 Nm ± 2 Nm
Î
Connect the WEH
®
Connector to a test piece a number of times. Visually check the
connector for proper clamping and sealing function and that the clamping jaws
are gripping correctly.
Attention:
During the next pressure test, apply the test pressure to the connector
and media line only gradually.
MD-10036-L51-R1.1.0-03
Page 27
Operating instructions
AE