54
of
68
TECHNICIANS manual
14.7.4 Wiring diagram cod. WY18090016 - WY18090017 *GICAR*
CN2
CN1
CN3
F1
JP8
CT1
CT2
CT3
CT4
TE2
TE1
CLS
SL
NE
BL
NE
MA
MA
MA
MA
GV
RO
BL
VE
VE
VE
VE
VE
VE
CV4
CV3
CV2
CV1
IP
MB
RO
RO
RO
RO
RO
RO
RO
RO
BL
VE
BL
VE
BL
VE
BL
VE
BI
RO
F2
JP3
JP6
JP4
JP1
JP2
JP5
CT
SCT
LA
PR
SA
CO
RE
400V
IST
R
S
T
N
MA BL
NE
GR GV
CAB
MA
BL
IM1
IM2
IM3
IM4
CAL
EVT
EV1
EV4
EVC
EV3
EV2
MP
13
9
5
1
3
7
11
15
16
12
8 4
2
6
10
14
FP1
FP2
O
O
O
O
JUMPER
INSERTED
NOT INSERTED
JP1
Serial connection enabled
Serial connection disabled
JP2
Pre-infusion enabled
Pre-infusion disabled
JP3
Programming enabled
Programming disabled
JP4
Boiler filling with pump
Boiler filling without pump
JP5
Configuration “W”
Configuration “C”
JP6
Tea dispensing with pump
Tea dispensing without pump
JP8
Control D
I/O Interface
BI
White
BL
Blue
CAB
Power cable
CAL
Boiler
CLS
Serial connector
CN1
Power supply
CN2
Low voltage connector
CN3
Service outputs connector
CO
Power switch
CT
Supply connector
CT1
Push button panel connector GR1
CT2
Push button panel connector GR2
CT3
Push button panel connector GR3
CT4
Push button panel connector GR4
CV1
Volumetric counter GR1
CV2
Volumetric counter GR2
CV3
Volumetric counter GR3
CV4
Volumetric counter GR4
EV1
Solenoid valve GR1
EV2
Solenoid valve GR2
EV3
Solenoid valve GR3
EV4
Solenoid valve GR4
EVC
Boiler filling solenoid valve
EVT
Tea solenoid valve
F1
Motor pump fuse (500mA)
F2
Inlet fuse (6.3A)
FP1(*) Motor pump UL (OPD) fuse
FP2(*) UL (OPD) Fuse for 230V
GR
Grey
GV
Yellow-green
IC2
Eprom
IM1
GR1 manual switch
IM2
GR2 manual switch
IM3
GR3 manual switch
IM4
GR4 manual switch
IP
Programming switch
IST
Cup heater switch
LA
Indicator light
MA
Brown
MB
Push button panel membrane
MP
Motor pump
NE
Black
PR
Pressure switch
RE
Resistance
RO
Red
SA
Resistance safety device
SL
Boiler level probe
TE 1
Tea dose
TE 2
Not managed
VE
Green
(*) Fuses for UL versions with plug with
a greater capacity than 30A