
SSW7000 | 9-6
9.2.
CONTROL DATA
Table 9.13: Control data.
Supply
Control voltage
Control Unit Version 2:
- 110 to 230 Vac (-15 % ( 93,5 Vac ) to 10 % ( 253 Vac ) ) or 125 to 320 Vdc
Control Unit Version 3:
- 100 to 230 Vac (-15 % ( 85 Vac ) to 10 % ( 253 Vac ) ) or 110 to 320 Vdc
*Note: The values informed are specific for the Control Units; they do not cover other components of the
SSW7000, such as contactor coils.
Frequency
„
(50 a 60 Hz): (±10 %) or (45 a 66 Hz)
Consumption
110 Vac:
- Continuous: 1400 mA (mec. A, B, C), 2700 mA (mec. D)
- Peak: 9,5 A (mec. A, B, C), 18 A (mec. D)
220 Vac:
- Continuous: 700 mA (mec. A, B, C), 1400 mA (mec. D)
- Peak: 6,0 A (mec A, B, C), 12,0 A (mec. D)
Control
Method
Voltage ramp
Current limit
Pumb control
Torque control
Current ramp
Inputs
Digital
6 isolated digital inputs, 24 Vdc, with programmable functions
Analog
2 differential inputs isolated by differential amplifier
AI1 with a 12 bit resolution
AI2 with 11bit resolution + sign, (0 to 10) V, (0 a 20) mA or (4 to 20) mA
Impedance: 400 kΩ for (0 to 10 V), 500 Ω for (0 a 20 mA) or (4 to 20 mA),
programmable functions
Outputs
Digital
3 relays with NO/NC contacts, 240 Vac, 1 A, programmable functions
Analog
2 isolated outputs,, (0 a 10 V) RL ≥ 10 kΩ (maximum load), 0 to 20 mA or 4
to 20 mA RL ≤ 500 Ω, 11 bit resolution, programmable functions
HMI
Human Machine Interface
Standard HMI
9 keys: Start/Stop, Increment, Decrement, rotation direction, Jog,
Local/remote, right soft key and Left soft key
Graphic LCD display
It allows access/modification of all the parameters
Indication accuracy
-
Current 3% of the rated current
Accessible at the cabinet door
Safety
Main protections
Under-, overcurrent and current imbalance
Under-, overvoltage and voltage imbalance
Under-, overtorque and active overpower
Phase loss
Inverted phase sequence
Power arm overtemperature
Motor overload
Motor overtemperature (optional)
External fault
Ground fault by voltage or by current
Power arm faults
Power contactor faults
Control board faults
Communication fault of the HMI and between control boards
Communication network faults
Programming error
For more details and more implemented functions, refer to the programming
manual
Enclosure
IP41
Standard cabinet, SSW7000A and SSW7000D
IP54
Compact cabinet, SSW7000B and SSW7000C
PC connection for
programming
USB connector
USB standard Ver. 2.0 (basic speed)
USB plug Type B “device”
Interconnection cable: Standard host/device shielded USB cable
Содержание SSW7000
Страница 1: ...Motors Automation Energy Transmission Distribution Coatings Soft Starter SSW7000 User s Manual ...
Страница 2: ......
Страница 3: ...User s Manual Series SSW7000 Language English Document Number 10001461783 08 Publication Data 11 2019 ...
Страница 4: ...Summary of Revisions ...
Страница 8: ...Contents ...
Страница 24: ...SSW7000 4 2 HMI ...
Страница 72: ...SSW7000 7 6 First Energization ...
Страница 74: ...SSW7000 8 2 Accessories ...