SSW7000 | 5-22
NOTE!
All the power supply connection cables must have medium voltage insulation, according to the
following specifications: 15 kVac, 200 ºC (392 ºF), 14 AWG or superior.
Table 5.18: Identification of the power supply cables of the electronic boards of the power arms
Power Supply cable Identification
Identification on the Arm
A1 – Power supply cable
X1:1
A2 – Power supply cable
X1:2
A3 – Power supply cable
X1:3
A4 – Power supply cable
X1:4
(a)
(b)
(c)
Figure 5.27 (a) a (c): Details of the cable installation on the power arms SSW7000A
Figure 5.27 (d): Details of the cable installation on the power arms SSW7000D