MAINTENANCE 

 

7.1

 

GENERAL 

 
A proper maintenance program for electric motors 
includes the following recommendations: 

 

Keep the motor and the associated equipment clean; 

 

Measure the winding insulation resistance periodically; 

 

Measure the temperature of windings, bearings and 
cooling system periodically;   

 

Check the wear, operation of the lubrication system and 
useful life of the bearings; 

 

Measure the motor vibration levels; 

 

Inspect the cooling system; 

 

Inspect associated equipment; 

 

Inspect all the motor accessories, protections and 
connections, ensuring that they are operating properly; 

 

 

ATTENTION 

Noncompliance with the recommendations 
of section 7.1 may cause undesired 
stoppages of the equipment. 
The frequency of such inspections depends 
on the local application conditions. 
Every time that it becomes necessary to 
transport the motor, the shaft must be 
properly locked to prevent damages to the 
bearings. Use the device supplied with the 
motor to lock the shaft. 
If the motor requires reconditioning or 
replacement of any damaged part, consult 
WEG. 

 

7.2

 

GENERAL CLEANING 

 

 

Keep the frame clean, without external accumulation of 
oil or dust, in order to facilitate the heat exchange with 
the environment; 

 

The inside of the motor must also be kept clean, free of 
dust, debris and oils;  

 

For cleaning, use brushes or clean cotton cloths. If the 
dust is not abrasive, the cleaning must be done with an 
industrial vacuum cleaner, “aspiring” the dirt from the 
fan cover and the  dust accumulated on the fan blades 
and on the frame; 

 

Debris impregnated with oil or moisture can be 
removed with a cloth soaked in appropriate solvents;                 

 

Clean the terminal boxes when necessary. Terminals 
and connectors must be kept clean, free of rust and in 
perfect operating conditions. Avoid the presence of 
grease or verdigris in the connection parts. 

 

7.3

 

WINDING MAINTENANCE 

 
To obtain more satisfactory operation and a longer life of 
the motor, the windings should be inspected and cleaned 
annually. 
 

7.3.1

 

Winding inspection 

 
Yearly, the windings must be submitted to a complete 
visual inspection, recording and repairing all and every 
damage or defect observed. 

The winding insulation resistance measurements must be 
done at regular intervals, especially during humid weather 
and after prolonged motor stoppages. 
Low values or sudden variations in the insulation 
resistance must be investigated. 
The windings must be submitted to complete visual 
inspections at frequent intervals, recording and repairing 
all and every damage or defect observed. 
The winding insulation resistance can be increased up to 
an adequate value in the points where it is low (as a result 
of excessive dust and moisture) by means of the dust 
removal and by drying the winding moisture. 
 

7.3.2

 

Winding cleaning 

 
In order to obtain a more satisfactory operation and a 
longer useful life of the insulated windings, it is 
recommended to keep them free of dirt, oil, metal dust, 
contaminants, etc.  
Therefore, it is necessary to inspect and clean the 
windings periodically, according to the recommendations 
of the "Maintenance Plan" of this manual. If reimpregnation 
is necessary, consult WEG. 
The windings may be cleaned with an industrial vacuum 
cleaner with a non-metallic crevice tool or just a dry cloth. 
For extreme dirt conditions, it may be necessary to use a 
proper liquid solvent for cleaning. This cleaning must be 
quick to prevent prolonged exposure of the windings to 
the solvent effects. 
After being cleaned with solvents, the windings must be 
completely dried. 
Measure the insulation resistance and the polarization 
index in order to assess the winding insulation conditions. 
Winding drying time after cleaning varies depending on the 
weather conditions such as temperature, humidity, etc. 
 

 

DANGER 

Most solvents currently used are highly 
toxic and/or flammable.  
Solvents must not be used in the straight 
parts of the coils of high-voltage motors, 
because they may affect the protection 
against corona effect. 

 

7.3.3

 

Inspections 

 
The following inspections must be carried out after the 
windings are carefully cleaned: 

 

Check the insulations of the winding and connections; 

 

Check if spacers, bindings, slot wedges, bandages and 
supports are properly fixed; 

 

Check for breaks, faulty welds, short-circuit between 
turns and against the frame in the coils and 
connections. In case any fault is detected, consult 
WEG. 

 

Ensure that all cables are properly connected and that 
terminal fixation components are duly tightened. 
Retighten, if necessary. 

 

7.3.4

 

Reimpregnation 

 
If any layer of resin on the windings is damaged during 
cleaning or inspection, such parts must be corrected with 
adequate material (in this case,  consult WEG). 

Содержание M line Series

Страница 1: ...Motors I Automation I Energy I Transmission Distribution I Coatings Low and high voltage three phase induction motors M line Squirrel cage rotor Vertical Installation Operation and Maintenance Manual...

Страница 2: ......

Страница 3: ...Installation Operation and Maintenance Manual Document Number 11371757 Models MGA MGP MGD MGT MGV MGF MGR MGI MGW and MGL Language English Revision 7 May 2018...

Страница 4: ......

Страница 5: ...lly before proceeding with the installation operation or maintenance of the motor in order to ensure safe and reliable operation of your equipment and facility If you need any further information plea...

Страница 6: ......

Страница 7: ...olling bearing 17 3 3 3 5 3 Sleeve bearing 17 3 3 3 6 Terminal boxes 17 3 3 3 7 Air water heat exchanger 18 3 3 3 8 Cleanliness and conservation of the motor during storage 18 3 3 3 9 Inspections and...

Страница 8: ...2 Base loads 29 4 8 3 Motor mounting 29 4 8 3 1 Motor with solid shaft and flange 29 4 8 3 2 Motor with hollow shaft and flange 29 4 8 4 Anchor plate set 29 4 8 5 Natural frequency of the base 30 4 8...

Страница 9: ...sembly 42 7 9 2 Oil lubricated rolling bearing 42 7 9 2 1 Lubrication instructions 43 7 9 2 2 Oil type 43 7 9 2 3 Oil change 43 7 9 2 4 Bearing operation 43 7 9 2 5 Bearing disassembly 44 7 9 2 6 Bear...

Страница 10: ...www weg net 10 l Installation operation and maintenance manual Squirrel cage motor M line Vertical 11371757 14 WARRANTY TERM 56...

Страница 11: ...ors with major special features is necessary consult WEG All procedures and standards contained in this manual must be observed in order to ensure proper operation of the motor and the safety of the p...

Страница 12: ...ample keep people away avoid contact of children etc Those responsible for the safety of the installation must ensure that Only qualified personnel install and operate the equipment They have this man...

Страница 13: ...nals within the limits in accordance with the IEC60034 1 standard Voltage may vary within a range of 10 of the rated value Frequency may vary within a range of 5 to 3 of the rated value Figure 2 1 Vol...

Страница 14: ...ugs present in the terminal box holes These protections must remain in place until the moment of the final assembly A complete visual inspection of the motor must be carried out after removing the pac...

Страница 15: ...tor which is needed to ensure proper storage conditions Place the motor on platforms or foundations that ensure protection against humidity from the ground and prevent it from sinking into the soil Fr...

Страница 16: ...ckage must be covered with protection against dust moisture and other odd materials using resistant canvas or plastic The package must be placed on platforms or foundations that ensure protection agai...

Страница 17: ...rage period the following preservation procedures must be performed Close all the threaded holes with plugs Check if all the flanges e g oil inlet and outlet are closed If not they must be closed with...

Страница 18: ...ucts such as ammonia compounds and hydrogen sulfide are taken out of the radiator and not deposited inside 3 3 3 8 Cleanliness and conservation of the motor during storage The motor should be free of...

Страница 19: ...ons X Measure the circuit voltage and frequency X Check the function of the signal system if any X WHOLE MOTOR Perform external cleaning X X Check the painting conditions X Check the rust inhibitor on...

Страница 20: ...bled inspected and cleaned before starting the motor operation Reassemble the sleeve bearings and carry out lubrication Contact WEG to perform this procedure 3 3 4 3 Bearing lubrication Use the lubric...

Страница 21: ...this product from the grounding brush if any contact track on the shaft 4 2 2 Radial lock Depending on the bearing type a locking device may be installed in the upper bearing for radial shaft locking...

Страница 22: ...tions to the stator terminals Disconnect and insulate all CTs and PTs if any Ground the motor frame Measure the winding temperature Ground all temperature sensors Check the humidity The insulation res...

Страница 23: ...s and 1 minute Polarization Index Insulation assessment 1 or lower Unacceptable 1 5 Dangerous 1 5 to 2 0 Fair 2 0 to 3 0 Good 3 0 to 4 0 Very Good 4 0 Excellent ATTENTION If the measured insulation re...

Страница 24: ...with winding temperatures above the limits of the insulation thermal class the lifespan of the insulation and hence that of the motor will be significantly reduced or it may even result in the motor b...

Страница 25: ...that it is de energized before the motor is put into operation The values of the space heater supply voltage and power are informed in the connection diagram and in the specific plate affixed to the m...

Страница 26: ...e beginning the connection of the main cables and those of the accessories For the electrical connection of auxiliary equipment refer to their specific manuals 4 7 1 1 Main electrical connections The...

Страница 27: ...or connection diagrams 3 TERMINALS 6 TERMINALS 6 TERMINALS DAHLANDER Y LOWER SPEED YY HIGHER SPEED Y LOWER SPEED YY LOWER SPEED HIGHER SPEED 3 TERMINALS NEUTRAL 9 TERMINALS 12 TERMINALS YY Y YY Y 12 T...

Страница 28: ...ions 4 7 2 3 Rotation direction The rotation direction is indicated on the nameplate and must be observed looking to the shaft end at the motor drive end The rotation direction must be checked before...

Страница 29: ...e 6 Couple the motor shaft to the driven machine 7 Rotate the shaft of the set to ensure that it rotates freely 8 Align the equipment according to the procedure described in this manual 9 Tighten all...

Страница 30: ...horizontal planes Make the proper adjustments by placing shims under the motor The motor leveling must be checked with proper equipment NOTE At least 75 of the motor foot support surfaces must rest on...

Страница 31: ...rks as a pendulum supported by the upper coupling and the motor bearing 1 Fix the dial gauge by its magnetic base to the pump shaft and align it with the base surface motor shaft setting the dial gaug...

Страница 32: ...ing can be controlled with the insertion of a paper strip on which the trace of all teeth shows up after a gear turn 4 8 10 3 Belt drive Figure 4 15 Belt drive When a reduction or increase in speed is...

Страница 33: ...induction motors have a high starting current the time spent to accelerate loads with high inertia results in a quick rise of the motor temperature If the intervals between successive starts are too s...

Страница 34: ...ing parts of the motor must be protected to prevent accidents 15 The terminal box covers must be correctly fastened 16 Check if the power supply voltage and frequency comply with the data on the motor...

Страница 35: ...t start it is important to pay attention to unusual vibrations or noises If the bearing is not working silently and smoothly the motor must be shut down immediately In case of overheating the motor mu...

Страница 36: ...ct measurement of the shaft vibration The shaft vibration measured in these motors must comply with the IEC 60034 14 or NEMA MG 1 standard The alarm and trip values of Table 6 2 represent the acceptab...

Страница 37: ...ements must be done at regular intervals especially during humid weather and after prolonged motor stoppages Low values or sudden variations in the insulation resistance must be investigated The windi...

Страница 38: ...ove the radiator for maintenance use the following procedure 1 Close all the water inlet and outlet valves after stopping the ventilation 2 Drain the water through the radiator drain plugs 3 Remove th...

Страница 39: ...from being dragged into the rolling bearing For lubrication use only manual grease gun 7 9 1 2 Procedures for rolling bearing relubrication 1 Remove the drain plug 2 Clean with a cotton cloth around t...

Страница 40: ...0 to 150 0 94 Table 7 3 shows the most common rolling bearings used in vertical motors the quantity of grease and the speed limit for using alternative greases Table 7 3 Application of alternative gre...

Страница 41: ...ase change or for any damages arising from this change 7 9 1 7 Low temperature greases Table 7 4 Grease for application at low temperatures Manufacturer Grease Constant operating temperature C Applica...

Страница 42: ...move the KMT nut 9 5 Remove the screws 11 and 12 and remove the bearing hub 6 Remove the upper end shield 14 7 Move the intermediate ring and the inner bearing cap away from the bearing in order to ob...

Страница 43: ...s Between 85 and 90 C 8 000 hours Between 90 and 95 C 6 000 hours Between 95 and 100 C 4 000 hours The lifespan of the bearings depends on their operating conditions on the motor operating conditions...

Страница 44: ...olling bearing puller extract the set formed by the upper ring 130 lower ring 200 and rolling bearing 120 Figure 7 7 Lower bearing Figure 7 7 legend 10 Oil tank 20 Oil flinger 30 Oil guide 40 Bearing...

Страница 45: ...es place The water pressure must be 0 1 bar and the flow equal to 0 7 l s The pH must be neutral NOTE Under no circumstances can water leak into the oil tank because this will contaminate the lubrican...

Страница 46: ...ing of the oil level and its lubricating conditions Checking the bearing noise and vibration levels Monitoring of the operating temperatures and retightening of the fastening and mounting screws In or...

Страница 47: ...on the bearing protection system Alarm 110 C Trip 120 C The alarm temperature must be set 10 C above the operating temperature not exceeding the limit of 110 C 7 9 5 2 Disassembly assembly of the slee...

Страница 48: ...MBLY The following precautions must be taken when disassembling the motor 1 Before disassembling the motor disconnect the water cooling and lubrication pipes if any 2 Disconnect the motor electrical c...

Страница 49: ...437 290 M24 3 637 425 557 372 M27 3 926 615 810 538 M30 3 5 1260 838 1102 734 M33 3 5 1704 1130 1490 990 M36 4 2195 1459 1920 1277 M42 4 5 3507 2328 3070 2037 M48 5 5258 3488 4600 3052 Table 8 2 Screw...

Страница 50: ...mperature sensor for front and rear bearing Space heater Filter felt if any Grounding Brush Front and rear bearing for the fan motor if applicable Lubricant for bearings Vibration sensor for front and...

Страница 51: ...leaks and temperature x Lubricant quality control x Inspection of the bearing shell and shaft journal sleeve bearing x Lubricant change According to the period indicated on the bearing nameplate AIR...

Страница 52: ...s interrupted after the start Check the power cables The stator current oscillates under load with double the slip frequency Motor presents a humming noise during starting Rotor winding is interrupted...

Страница 53: ...ting conditions vibration etc bearing conditions The operating condition does not correspond to the nameplate data Keep the operating condition according to the nameplate or reduce the load Unbalance...

Страница 54: ...www weg net 54 l Installation operation and maintenance manual Squirrel cage motor M line Vertical 11371757 11 DECLARATION OF CONFORMITY...

Страница 55: ...product that has a long useful life however when it must be disposed WEG recommends that the materials of the packaging and of the product be properly separated and sent for recycling The non recycla...

Страница 56: ...s in lieu of all other warranties expressed or implied written or oral There are no implied warranties of merchantability or fitness for a particular purpose that apply to this sale No employee agent...

Страница 57: ...www weg net 11371757 Installation operation and maintenance manual Squirrel cage motor M line Vertical l 57 NOTES...

Страница 58: ...www weg net 58 l Installation operation and maintenance manual Squirrel cage motor M line Vertical 11371757...

Страница 59: ...remona Phone 39 374 340 404 www ferrarisrl it STIAVELLI IRIO S P A Via Pantano Blocco 16 Capalle 50010 Campi Bisenzio FI Phone 39 55 898 448 www stiavelli com JAPAN WEG ELECTRIC MOTORS JAPAN CO LTD Yo...

Отзывы: