Seq.

Action/Result

Display Indication

12

 

-

If necessary, change 

“P0401 – Motor 

Rated Current”

 ” parameter. This change 

will affect P0156, P0157, P0158 and P0410.

 

-

 Press  the 

 key to the next parameter.

13

 

-

If necessary, change 

“P0404 – Motor 

Rated Power”

 parameter. This change 

will affect P0410.

 

-

 Press  the 

 key to the next parameter.

14

 

-

If necessary, change 

“P0403 – Motor 

Rated Frequency”

 parameter. This 

change will affect P0402.

 

-

 Press  the 

 key to the next parameter.

15

 

-

If necessary, change 

“P0402 – Motor 

Rated Speed”

. This change will affect 

P0122 to P0131, P0135, P0182, P0208, 
P0288 and P0289.

 

-

 Press  the 

 key to the next parameter.

16

 

-

If necessary, change 

“P0405 – Encoder 

Pulses Number ”

 according to the 

encoder model.

 

-

 Press  the 

 key to the next parameter.

17

 

-

In this moment the keypad presents 
the option to perform 

“Self-tunning”

The Self-tunning should be performed 
whenever it is possible. Press 

“ENTER/

MENU”

 key to access parameter P0408 

and press 

 to select the desired 

option. Then, press 

“ENTER/MENU”

 

to start the Self-tunning. The keypad 
will show 

“CONF”

 and 

“RUN”

status 

simultaneously during the self-tunning. 
At the end of the self-tuning, the 

“RUN”

 

status is automatically erased and the 
content of P0408 automatically goes 
back to the.

18

 

-

Press 

BACK /ESC

 key to finish the 

start-up routine.

 

-

Press 

BACK/ESC

 key again to get back 

to the monitoring mode.

Figure 11:

 Start-up Oriented to the vector mode

APPENDIX 1 – TECHNICAL SPECIFICATIONS

Table A.12:

 Technical specifications of CVW300G2 model

Model

CVW300A0400D0NB66G2

Input rated voltage

24...48 V

Input voltage limits

18...66 V

Output rated current

40 °C

200 A

50 °C

200 A

Peak output current

400 A

Output voltage

Vcc

2

Dissipated power

Rated

300 W

Peak

910 W

Weight

5,9 kg

Environment temperature

-25...50°C (-13...122°F)

Seq.

Action/Result

Display Indication

1

 

-

Monitoring mode.

 

-

Press the 

ENTER/MENU

 key to get in to 

the first level of the programming mode.

2

 

-

 The 

PARAM

 group is selected, press the 

 or 

 keys to select the 

STARTUP

 

group.

3

 

-

 Press 

ENTER/MENU

 when the group is 

selected.

4

 

-

 The  parameter 

“P0317 – Oriented 

Startup”

 is then selected, press the  

ENTER/MENU

 to get into the parameter 

content.

5

 

-

 Change the parameter P0317 to 

“1 – Yes”

using the 

 key.

6

 

-

 When the desired value is reached press  

ENTER/MENU

 to save.

7

 

-

In this moment the Oriented Star t-
uproutine is initiated and the 

“CONF”

 

status is indicated at the keypad (HMI).

 

-

The parameter 

“P0000 – Access to 

Parameters”

 is selected. Change the 

password to set the remaining parameters 
if necessary.

 

-

 Press  the 

 key to the next parameter.

8

 

-

If necessary, change 

“P0296 – Battery 

Rated Voltage”

. This change will affect 

P0151, P0185, and P0400.

 

-

Press the 

 key to the next parameter.

9

 

-

Set parameter 

“P0202 – Typeof Control”

 

pressing 

“ENTER/MENU”

. Press the  

key to select the desired option: 

“[1] = 

Sensorless”

 or 

“[2] = Encoder”

.

 

This 

modification resets the content of P0410. 
Then, press 

“ENTER/MENU”

. There are 

three options to exit the oriented start-up:
1 - Running the Self-tunning.
2 - Manual settings of parameters from 

P0409 to P0413.

3 - Changing P0202 from vector to scalar.

 

-

 Press the  

 key to the next parameter.

10

 

-

If necessary, change 

“P0398 – Motor 

Service Factor” 

parameter. This change 

will affect the current and the time of the 
motor overload protection operation.

 

-

 Press  the 

 key to the next parameter.

11

 

-

If necessary, change 

“P0400 – Motor 

Rated Voltage” 

parameter. This change 

corrects the output voltage by the factor 
“x = P0400/ P0296”. 

 

-

 Press  the 

 key to the next parameter.

Содержание CVW300G2

Страница 1: ...n Coatings Variable Speed Drive for Electric Traction Convertidor de Frecuencia para Tracci n El ctrica Inversor de Frequ ncia para Tra o El trica CVW300G2 Installation Guide Gu a de Instalaci n Guia...

Страница 2: ......

Страница 3: ...Installation Guide Series CVW300G2 Language English Document 10005692328 00 Date 06 2018...

Страница 4: ......

Страница 5: ...ANICAL INSTALLATION 7 GENERAL MOUNTING CONSIDERATIONS 7 ELECTRICAL INSTALLATION 8 POWER WIRING DIAGRAMS 8 CONTROL WIRING DIAGRAMS 9 BASIC CONNECTION FOR FIRST POWER UP 9 INTEGRAL KEYPAD HMI 10 BEFORE...

Страница 6: ......

Страница 7: ...the CVW300G2 according to this guide and to the current legal safety procedures 2 Use the protection equipment according to the established regulations 3 Provide first aid NOTE The CVW300G2 may inter...

Страница 8: ...e 3 on page 8 shows the basic power wiring diagram of the inverter with the battery and the motor Figure 3 Drive wiring diagram It is recommended the use of a contactor between the drive and the batte...

Страница 9: ...10 15 REF Negative analog reference XC10 16 CONTACTOR Drive of the main contactor XC10 17 UDA Electronics power supply XC10 18 XCA Main contactor feedback XC10 19 DI1 Digital inputs XC10 20 DI2 XC10 2...

Страница 10: ...value USB communication port 1 Press this key to go back to the monitoring mode 2 Press this key to go back to the previous level in the parameterization mode 3 Press this key to cancel the new value...

Страница 11: ...de pressing the ENTER MENU key will switch to the programming mode Parameterization Mode Level 1 This is the first level of the programming mode It is possible to chose the parameter group by using th...

Страница 12: ...nt 40 C 200 A 50 C 200 A Peak output current 400 A Output voltage Vcc 2 Dissipated power Rated 300 W Peak 910 W Weight 5 9 kg Environment temperature 25 50 C 13 122 F Seq Action Result Display Indicat...

Страница 13: ...Gu a de Instalaci n Serie CVW300G2 Idioma Espa ol Documento 10005692328 00 Data 06 2018...

Страница 14: ......

Страница 15: ...NSIDERACIONES GENERALES DE MONTAJE 17 INSTALACI N EL CTRICA 18 DIAGRAMAS DE CONEXI N DE POTENCIA 18 DIAGRAMAS DE CONEXI N DE CONTROL 19 CONEXI N B SICA PARA PRIMERA ENERGIZACI N 19 INTERFAZ HOMBRE M Q...

Страница 16: ...ndice...

Страница 17: ...en otros equipos electr nicos Siga las instrucciones de instalaci n para minimizar tales efectos DESCRIPCI N PRINCIPAL DEL CVW300G2 El convertidor de frecuencia CVW300G2 es un producto de alto desempe...

Страница 18: ...lizaci n de un contactor entre el convertidor y la bater a de modo de protegerla La relaci n de los contactores sugeridos est en la Tabla 2 en la p gina 18 Para m s detalles consulte el manual del usu...

Страница 19: ...Accionamiento del contactor principal XC10 17 UDA Alimentaci n de la electr nica XC10 18 XCA Feedback del contactor principal XC10 19 DI1 Entradas digitales XC10 20 DI2 XC10 21 DO1 NF Salida digital...

Страница 20: ...na al nivel anterior Define la direcci n de rotaci n del motor Se activa cuando P0223 2 o 3 en LOC y o P0226 2 o 3 en REM Altera entre el modo LOCAL y o REMOTO Se activa cuando P0220 2 o 3 Puerto de c...

Страница 21: ...ANTES DE LA ENERGIZACI N 1 Verifique si las conexiones de potencia y de control est n correctas y firmes 2 Verifique las conexiones del motor y si la corriente y la tensi n del motor est n de acuerdo...

Страница 22: ...ci n corrige la tensi n de salida por el factor x P0400 P0296 Presione la tecla para el pr ximo par metro Sec Acci n Resultado Indicaci n en el Display 12 Si es necesario altere el contenido de P0401...

Страница 23: ...Guia de Instala o S rie CVW300G2 Idioma Portugu s Documento 10005692328 00 Data 06 2018...

Страница 24: ......

Страница 25: ...7 CONSIDERA ES GERAIS DE MONTAGEM 27 INSTALA O EL TRICA 28 DIAGRAMAS DE CONEX O DE POT NCIA 28 DIAGRAMAS DE CONEX O DE CONTROLE 29 CONEX O B SICA PARA PRIMEIRA ENERGIZA O 29 INTERFACE HOMEM M QUINA HM...

Страница 26: ......

Страница 27: ...ores de frequ ncia podem interferir em outros equipamentos eletr nicos Siga as instru es de instala o para minimizar estes efeitos DESCRI O PRINCIPAL DO CVW300G2 O inversor de frequ ncia CVW300G2 um p...

Страница 28: ...tor entre o inversor e a bateria de modo a proteger a mesma A rela o dos contatores sugeridos est na Tabela 2 na p gina 28 Para mais detalhes consultar o manual do usu rio Tabela 2 Contatores sugerido...

Страница 29: ...ca positiva XC10 15 REF Refer ncia anal gica negativa XC10 16 CONTATOR Acionamento do contator principal XC10 17 UDA Alimenta o da eletr nica XC10 18 XCA Feedback do contator principal XC10 19 DI1 Ent...

Страница 30: ...anterior Define a dire o de rota o do motor Ativa quando P0223 2 ou 3 em LOC e ou P0226 2 ou 3 em REM Altera entre o modo LOCAL e ou REMOTO Ativa quando P0220 2 ou 3 Porta de comunica o USB Figura 8 T...

Страница 31: ...a se para o modo parametriza o Modo Parametriza o N vel 1 Este o primeiro n vel do modo parametriza o poss vel escolher o grupo de par metro utilizando as teclas e Os campos display principal display...

Страница 32: ...rrige a tens o de sa da pelo fator x P0400 P0296 Pressione a tecla para o pr ximo par metro Seq A o Resultado Indica o no Display 12 Se necess rio altere o conte do de P0401 Corrente Nominal Motor Est...

Страница 33: ...NOTES NOTAS ANOTA ES...

Страница 34: ...WEG Drives Controls Automa o LTDA Jaragu do Sul SC Brazil Phone 55 47 3276 4000 Fax 55 47 3276 4020 S o Paulo SP Brazil Phone 55 11 5053 2300 Fax 55 11 5052 4212 automacao weg net www weg net 14400446...

Отзывы: