Variable Speed Drive for Electric Traction
E
ng
lis
h
10 | CVW300G2
In case the contactor used between the CVW300G2 and the battery
has an auxiliary contact, its wiring must be done according to
XC
10 P
in 1
8
XC
10 P
in 1
6
Figure 7:
Contactor wiring
NOTE!
In case the contactor does not have an auxiliary
contact, it is necessary to short the pins 17 and 18
of XC10; otherwise, the inverter will show fault F185.
INTEGRAL KEYPAD – HMI
The HMI for the CVW300G2 is supplied as an accessory and must
be purchased separately. For detailed information please refer to the
CVW300G2 user's manual.
- Press this key to accelerate the motor up to the speed set in P0122. The motor
speed is maintained while the key is pressed. When the key is released the
motor decelerates up to its complete stop.
This function is active when all the following conditions are met:
1. Start/Stop = Stop.
2. General Enable = Active.
3. P0225 = 1 in LOC and/or P0228 = 1 in REM.
1. Press this key to
decrease the speed.
2. Press this key to go to
the next group.
3. Press this key to go
back to the previous
parameter.
4. Press this key
to decrease the
parameter value.
1. Press this key to enter
in the programming
mode.
2. Press this key to select
the desired parameter
group.
3. Press this key to show
the parameter.
4. Press this key to save
the parameter value.
- Press this key to
accelerate the motor
according to the
acceleration ramp time.
This option is active
when:
P0224 = 0 in LOC and/or
P0227 = 0 in REM.
- Press this key to
decelerate the motor
according to the
deceleration ramp time.
This option is active
when:
P0224 = 0 in LOC and/or
P0227 = 0 in REM.
1. Press this key to go
back to the previous
group.
2. Press this key to go to
the next parameter.
3. Press this key
to increase the
parameter value.
- USB communication
port
1. Press this key to
go back to the
monitoring mode.
2. Press this key to
go back to the
previous level in the
parameterization
mode.
3. Press this key to
cancel the new value
and go back to the
previous level.
- Press this key to
define the motor
rotation.
This option is active
when:
P0223 = 2 or 3 in
LOC and/or
P0226 = 2 or 3 in
REM.
- Press this key to
toggle between
LOCAL and REMOTE
mode.
This option is active
when:
P0220 = 2 or 3.
Figure 8:
Operator keys
NOTE!
It is necessary to set the password at P0000 for
parameter modification; otherwise the parameters
contents can only beviewed.
The default password for P0000 is 5. It is possible
to change the password at P0200. Refer to the
CVW300G2 user's manual.
Inverter
status
Local/Remote
(commands and
references source)
Motor
rotation
Secondary
display
Variable
unit (shows
the value
of the main
display)
Variable
monitoring
bar graph
Menu
(parameters
group
selection)
– only one
parameter
group is
shown
ateach time.
Main display
Figure 9:
Display sections
Parameter groups available at the Menu:
PARAM:
all parameters.
READ:
only the reading parameters.
MODIF:
only the parameters changed compared to the factory
default.
BASIC:
basic application parameters.
MOTOR:
parameters related to motor data control.
I/O:
parameters related to the digital and analog inputs/outputs.
NET:
parameters related to the communication protocol.
HMI:
parameters for the keypad configuration.
SPLC:
parameters related to the SoftPLC function.
STARTUP:
parameters for the oriented startup.
Inverter status:
LOC:
command source or local reference.
REM:
command source or remote reference.
:
motor rotation according to the arrows.
CONF:
configuration. It indicates that the inverter is in the Oriented
Start-up routine or with in compatible parameter programming.
Refer section 5.6 Incompatibility Between Parameters in the user's
manual of the CVW300G2.
SUB:
Battery undervoltage.
RUN:
inverter enabled and/or DC braking activated.
Содержание CVW300G2
Страница 2: ......
Страница 3: ...Installation Guide Series CVW300G2 Language English Document 10005692328 00 Date 06 2018...
Страница 4: ......
Страница 6: ......
Страница 13: ...Gu a de Instalaci n Serie CVW300G2 Idioma Espa ol Documento 10005692328 00 Data 06 2018...
Страница 14: ......
Страница 16: ...ndice...
Страница 23: ...Guia de Instala o S rie CVW300G2 Idioma Portugu s Documento 10005692328 00 Data 06 2018...
Страница 24: ......
Страница 26: ......
Страница 33: ...NOTES NOTAS ANOTA ES...