background image

Signal Conectors Kit KCS-300

E

ng

lis

h

CVW300  |  7   

8.9 N to be sure of the retention fingers are holding 
the contact.

Retention fingers

holding contact

Pull back 

on wire

(a)

(b)

(c)

3.  After all required contacts have been inserted, the 

wedge lock must be closed to its locked position. 
Releasing the locking latches by squeezing them 
inward.

Squeeze locking latches to 

seat wedge lock (both slides)

4.  Slide the wedge lock into the housing until it is flush 

with the housing.

Wedge lock flush 

with housing

5 DISASSEMBLY PROCEDURE

The plug must be disassembled (contacts removed) 
as it follows:

1.  Insert a 4.8 mm wide screwdriver blade between the 

mating seal and one of the red wedge lock tabs.

2.  Pry open the wedge lock to the open (as shipped) 

position.

3.  While rotating the wire back and forth over a half turn 

(one-quarter turn in each direction), gently pull the 
wire until the contact is removed.

Wedge 

lock tab

For further details about the conectors, please refer 
to www.te.com.

Содержание CVW-300

Страница 1: ...Conectors Kit KCS 300 Kit de Conectores de Se al KCS 300 Kit de Conectores de Sinal KCS 300 CVW 300 Assembling Guide Gu a Montage Guia de Montagem Motors Automation Energy Transmission Distribution Co...

Страница 2: ......

Страница 3: ...DURE 7 NDICE 1 CONTENIDO DEL PAQUETE 8 2 FUNCIONES DE LOS TERMINALES DE LOS CONECTORES 8 3 INSTRUCCIONES PARA CRIMPADO DE LOS TERMINALES 9 4 PROCEDIMIENTO DE MONTAJE 9 5 PROCEDIMIENTO DE DESMONTAJE 10...

Страница 4: ...aci n el ctrica antes de proceder a cualquier trabajo en este equipo Solamente profesionales calificados pueden efectuar la instalaci n y mantenimiento Obedezca las normas nacionales y locales as como...

Страница 5: ...ONNECTORS PIN FUNCTION XC9 Black XC10 Gray Pin Function Pin Function 1 A HMI 1 5 V_ENC 2 B HMI 2 A 3 15 V 3 A 4 DGND 4 B 5 A 5 B 6 B 6 Z 7 CANH 7 Z 8 CANL 8 DGND 9 15 V 9 15 V 10 DI3 10 DO2 11 DI4 11...

Страница 6: ...wrapped around wire insulation leaving no sharp points to damage rubber wire seal 0 25 mm max 0 13 mm min front bellmouth 0 25 mm max cutoff tab 0 13 0 75 mm rear bellmouth Wire barrel shall be closed...

Страница 7: ...ides 4 Slide the wedge lock into the housing until it is flush with the housing Wedge lock flush with housing 5 DISASSEMBLY PROCEDURE The plug must be disassembled contacts removed as it follows 1 Ins...

Страница 8: ...UNCIONES DE LOS TERMINALES DE LOS CONECTORES XC9 Negro XC10 Gris Terminal Funci n Terminal Funci n 1 A HMI 1 5 V_ENC 2 B HMI 2 A 3 15 V 3 A 4 DGND 4 B 5 A 5 B 6 B 6 Z 7 CANH 7 Z 8 CANL 8 DGND 9 15 V 9...

Страница 9: ...ta rea Los alambres y el aislamiento deben estar visibles Las extremidades del cilindro aislante deben envolver al aislamiento del alambre sin puntas que puedan da ar el sellado de goma del alambre 0...

Страница 10: ...ios deber ser cerrada la tapa frontal de cierre Traba de apriete para asentar la wedge lock ambos lados 4 Apriete la tapa frontal de cierre en direcci n al conector hasta trabarla Wedge lock nivelada...

Страница 11: ...Kit de Conectores de Se al KCS 300 CVW300 11 Espa ol Aba da wedge lock Para m s detalles acerca de los conectores consulte www te com...

Страница 12: ...ntagem 2 FUN ES DE CADA PINO DO CONECTOR XC9 Preto XC10 Cinza Pino Fun o Pino Fun o 1 A HMI 1 5 V_ENC 2 B HMI 2 A 3 15 V 3 A 4 DGND 4 B 5 A 5 B 6 B 6 Z 7 CANH 7 Z 8 CANL 8 DGND 9 15 V 9 15 V 10 DI3 10...

Страница 13: ...s nesta rea Fios e isolamento devem estar vis veis As extremidades do cilindro isolante devem envolver o isolamento do fio sem pontas que possam danificar a veda o de borracha do fio 0 25 mm m x 0 13...

Страница 14: ...ar o fio para tr s a b c 3 Ap s todos os contatos necess rios terem sido inseridos a tampa frontal de travamento deve ser fechada Trava de aperto para assentar wedge lock ambos os lados 4 Aperte a tam...

Страница 15: ...5 Portugu s 3 Enquanto gira o cabo de um lado a outro em meia volta um quarto de volta em cada dire o puxe tire suavemente o cabo at que o terminal esteja removido Aba da wedge lock Para maiores detal...

Страница 16: ...NOTES NOTAS ANOTA ES...

Страница 17: ...NOTES NOTAS ANOTA ES...

Страница 18: ...NOTES NOTAS ANOTA ES...

Страница 19: ......

Страница 20: ...03152018 00 12975711 WEG Drives Controls Automa o LTDA Jaragu do Sul SC Brazil Phone 55 47 3276 4000 Fax 55 47 3276 4020 S o Paulo SP Brazil Phone 55 11 5053 2300 Fax 55 11 5052 4212 automacao weg net...

Отзывы: