General Information
CPW17 | 9
E
ng
lis
h
2.4 TERMS AND DEFINITIONS
CPW17
Emergency Stop Safety Relay from WEG Company.
PLMP
Standard screw fixing adapter from WEG Company.
CAT
Category: Classification of the safety-related parts of a control system in respect of their resistance to faults and
their subsequent behavior in the fault condition, and which is achieved by the structural arrangement of the parts,
fault detection and/or by their reliability.
[EN ISO 13849-1:2015]
PL
Performance Level: Discrete level used to specify the ability of safety-related parts of control systems to perform
a safety function under foreseeable conditions.
[EN ISO 13849-1:2015]
SIL
Safety Integrity Level: Discrete level for specifying the safety integrity requirements of the safety functions, where
safety integrity level 4 has the highest level of safety integrity and safety integrity level 1 has the lowest.
[IEC 61508:2010]
PFD
Probability of Dangerous Failure Demand: Safety unavailability of safety-related system to perform the specified
safety function when a demand occurs from the control system.
[IEC 61508:2010]
SFF
Safe Failure Fraction: Property of a safety related element that is defined by the ratio of the average failure rates
of safe plus dangerous detected failures and safe plus dangerous failures.
[IEC 61508:2010]
SIL CL
SIL Claim Limit: Maximum SIL that can be claimed for a safety related electrical control system in relation to
architectural constraints and systematic safety integrity.
[IEC 62061:2005]
PFHd
Probability of dangerous Failure per Hour: Average probability of dangerous failure within 1 h.
[IEC 62061:2005]
Содержание CPW17
Страница 2: ...User s Manual Series CPW17 Language English Document 10007588965 00 Publishing Date 10 2020...
Страница 18: ...Manual del Usuario Serie CPW17 Idioma Espa ol Documento 10007588965 00 Fecha de Publicaci n 10 2020...
Страница 34: ...Manual do Usu rio S rie CPW17 Idioma Portugu s Documento 10007588965 00 Data de Publica o 10 2020...