Abnormal smell mist
New unit
Take out water tank, open
cover, let it stay 12 hours in
cool position
Dirty water or long time
staying water
Cleaning water tank, fill in
clear water
Power lamp on, unit doesn’t
work
Too much water in the
water basin
Pull out same water from
the water basin, closed the
cover of water tank tightly
Mist fog is too small
Too much scale in the water
basin
Clean transducer
Water is too dirty or water
kept too long in the tank
Clean water tank, change
to fresh clear water
Abnormal noise
Resonant in water tank
when water is too less
Fill water into water tank
Unit is on a unstable
surface
Move the unit to a stable
flat surface
Mist fog coming out from
around nozzle
There are gaps between the
nozzle and water tank
Dip the nozzle in water for
a while and then fix it to
the socket on water tank
Maintenance
In case when the water is hard which means water contains too much calcium and
magnesium, they can cause “white powder” problem and give limes on the surface of water
basin, transducer and inner surface of the water tank. Limes on the surface of transducer
will unable the unit work properly.
We recommend
1.Use cold boiled water or distilled water.
2.Clean the transducer, water tank and basin unit every week.
3.Change the water in water tank more often to keep it fresh.
4.Make sure to pull out the water from the water tank and dry the water basin before you
store the unit unused for a long period of time.
5.Clean the whole unit, and make sure that all parts of the unit are dried completely before
unused for a long period of time.