background image

5

IMPORTANT

Experience indicates that alcohol blended
fuels (called gasohol or using ethanol or
methanol) can attract moisture which leads to
separation and formation of acids during stor-
age. Acidic gas can damage the fuel system
of an engine while in storage.
To avoid engine problems, empty the fuel sys-
tem before storage for 30 days or longer.
Drain the gas tank, start the engine and let it
run until the fuel lines and carburetor are
empty. Use fresh fuel next season.
Never use engine or carburetor cleaner prod-
ucts in the fuel tank or permanent damage may
occur. See the STORAGE section for addi-
tional information.

HOW TO STOP YOUR UNIT

S

To stop the engine, push and release the
engine ON/STOP switch. The switch will
automatically return to the ON position.
Wait 5 seconds before attempting to restart
unit to allow switch to reset.

S

If engine does not stop, move choke to the
FULL CHOKE position.

Engine
ON/STOP
Switch

Choke Lever

FULL

HALF

OFF

HOW TO START YOUR UNIT

WARNING:

The trimmer head will

turn while starting the engine. Avoid any con-
tact with the muffler. A hot muffler can cause
serious burns.

STARTING A COLD ENGINE (or a
warm engine after running out of
fuel)

Starting Position

1.

Set unit on a flat surface.

2.

Slowly press the primer bulb 6 times.

3.

Move choke lever to the FULL CHOKE
position.

4.

Squeeze the throttle trigger fully and hold
through all remaining steps.

Choke
Lever

Primer Bulb

Starter Handle

Muffler

5.

Pull starter rope handle sharply until engine
sounds as if it is trying to start, but do not
pull rope more than 6 times.

6.

As soon as engine sounds as if it is trying to
start, move choke lever to HALF CHOKE
position.

7.

Pull starter rope sharply until engine runs,
but no more than 6 pulls.

NOTE:

If the engine doesn’t start after 6

pulls (at the HALF CHOKE position),
move the choke lever to the FULL
CHOKE position and press the primer
bulb 6 times. Squeeze and hold the
throttle trigger and pull the starter rope 2
more times. Move the choke lever to the
HALF CHOKE position and pull the start-
er rope until the engine runs, but no more
than 6 pulls. If the engine still doesn’t
start, it is probably flooded. Proceed to
STARTING A FLOODED ENGINE.

8.

Once the engine starts, allow it to run 10
seconds, then move the choke lever to
the OFF CHOKE position. Allow the unit
to run for 30 more seconds at OFF
CHOKE before releasing the throttle trig-
ger.

NOTE:

If engine dies with the choke le-

ver in the OFF CHOKE position, move
the choke lever to the HALF CHOKE
position and pull the rope until engine
runs, but no more than 6 pulls.

STARTING A WARM ENGINE

1.

Move the choke lever to the HALF CHOKE
position.

2.

Squeeze and hold the throttle trigger. Keep
throttle trigger fully squeezed until the en-
gine runs smoothly.

3.

Pull starter rope sharply until engine runs,
but no more than 5 pulls.

4.

Allow engine to run 15 seconds, then move
the choke lever to OFF CHOKE.

NOTE:

If engine has not started, pull starter

rope 5 more pulls. If engine still does not run, it
is probably flooded.

STARTING A FLOODED ENGINE

Flooded engines can be started by placing
the choke lever in the OFF CHOKE position;
then, pull the rope to clear the engine of ex-
cess fuel. This could require pulling the starter
handle many times depending on how badly
the unit is flooded.
If the unit

still

doesn’t

start,

refer to

TROUBLESHOOTING

TABLE

or

call

1-800-554-6723.

Содержание 530086930

Страница 1: ...r tous les avertisse ments et toutes les instructions de sécurité Tout défaut de le faire pourrait entraîner des blessures graves Instruction Manual Manual de Instrucciones Manuel d Instructions ENGLISH ESPAÑOL FRANÇAIS 530086930 4 24 02 Please do not return unit to retailer Por favor no devuelva el aparato al lugar de compra Veuillez ne pas retourner l outil au détaillant 1 800 554 6723 www weede...

Страница 2: ...hing or clothing with loosely hanging ties straps tassels etc They can be caught in moving parts S Being fully covered also helps protect you from debris and pieces of toxic plants thrown by spinning line S Stay Alert Do not operate this unit when you are tired ill upset or under the influence of al cohol drugs or medication Watch what you are doing use common sense S Wear hearing protection S Nev...

Страница 3: ...st monitor closely their physical condition and the condi tion of this tool SPECIAL NOTICE This unit is equipped with a temperature limiting muffler and spark arresting screen which meets the require ments of California Codes 4442 and 4443 All U S forest land and the states of California Idaho Maine Minnesota New Jersey Ore gon and Washington require by law that many internal combustion engines be...

Страница 4: ...OKE helps to supply fuel to the engine to aid in cold starting Activate the choke by moving the choke lever to the FULL CHOKE position Afterthe engine attempts to start move the choke lever to the HALF CHOKE position Once engine has started move the choke lever to the OFF CHOKE position BEFORE STARTING ENGINE WARNING Be sure to read the fuel information in the safety rules before you begin If you ...

Страница 5: ...e sounds as if it is trying to start move choke lever to HALF CHOKE position 7 Pull starter rope sharply until engine runs but no more than 6 pulls NOTE If the engine doesn t start after 6 pulls at the HALF CHOKE position move the choke lever to the FULL CHOKE position and press the primer bulb 6 times Squeeze and hold the throttle trigger and pull the starter rope 2 more times Move the choke leve...

Страница 6: ... the line is worn down to 2 inches 5 cm or less more than one tap will be required to ob tain the most efficient line length WARNING Use only 0 080 2 mm diameter line Other sizes and shapes of line will not advance properly and will result in im proper cutting head function or can cause se rious injury Do not use other materials such as wire string rope etc Wire can break off during cutting and be...

Страница 7: ...re attempting to restart unit to allow switch to reset Restart engine and continue S Fuel Tank Discontinue use of unit if fuel tank shows signs of damage or leaks S Debris Shield Discontinue use of unit if debris shield is damaged INSPECT AND CLEAN UNIT AND LABELS S After each use inspect complete unit for loose or damaged parts Clean the unit and labels using a damp cloth with a mild deter gent S...

Страница 8: ...cannot reach sparks or open flames from water heaters electric motors or switches furnaces etc S Store unit with all guards in place Position unit so that any sharp object cannot acci dentally cause injury S Store unit and fuel well out of the reach of children SEASONAL STORAGE Prepare unit for storage at end of season or if it will not be used for 30 days or more If your unit is to be stored for ...

Страница 9: ... accelerate lacks power or dies under a load 1 Clean or replace air filter 2 Clean or replace plug and regap 3 See Carburetor Adjustment in Service and Adjustments Section 4 Contact an authorized service dealer 5 Contact an authorized service dealer Engine smokes excessively 1 Choke partially on 2 Fuel mixture incorrect 3 Air filter dirty 4 Carburetor requires adjustment 1 Adjust choke 2 Empty fue...

Страница 10: ...neglect or im proper maintenance of your small off road en gine Your emission control system includes parts such as the carburetor and the ignition system Where a warrantable condition exists POULAN WEED EATER will repair your small off road engine at no cost to you Expenses covered under warranty include diagnosis parts and labor MANUFACTURER S WAR RANTY COVERAGE If any emissions related part on ...

Страница 11: ...HOW TO FILE A CLAIM If you have any questions regarding your warranty rights and responsibilities you should contact your nearest authorized service center or call POULAN WEED EATER at 1 800 554 6723 WHERE TO GET WAR RANTY SERVICE Warranty services or re pairs shall be provided at all POULAN WEED EATER service centers Call 1 800 554 6723 MAINTENANCE REPLACEMENT AND RE PAIR OF EMISSION RELATED PART...

Отзывы: