All  Wedgelock  Couplers  are  fitted  with 

an Aluminum Data Plate (FIG 3.0.1). 

Information pertains to the product code, 

the carrier machine, product serial number, 

working load limit (for lifting purposes) and 

the maximum operating pressure. If any 

of the cells are left blank it means that 

the information is non-applicable to this 

attachment 

3.0 COUPLER IDENTIFICATION

SECTION 3: MAINTENANCE

WARNING: 

Wedgelock Quick Couplers that incorporate a factory fitted lifting eye 

will be labeled and marked with a Working Load Limit (WLL). The lifting eyes are 

designed in accordance with BS-2573:Part1. It is highly recommended that a Bow 

Type Shackle be used to connect to the lifting eye. See page 13.

3.0 SERVICING SCHEDULE 

Maintenance Required

Daily

Weekly

Check all pin retainers, bolts & nuts for tightness on the quick coupler and 

the attachments.

Lubricate all greaseing points – the attachment will have to be removed to 

access all grease points.

Check hydraulic hoses and fittings for any leaks or wear – replace 

immediately if required.

Check the quick coupler switch audible warning buzzer and lights are 

operating properly.

Check the full operation of all the moving parts within the quick coupler – 

repair or replace immediately if required.

Check the hydraulic cylinder mounting bolts for tightness – remedy if 

required.

Thoroughly clean the quick coupler and ensure there is no material build 

up around locking cylinder, wedge or I-Lock™ safety system.

Thoroughly clean the quick coupler and ensure there is no material build 

up around locking cylinder, wedge or I-Lock™ safety system.

(Fig 3.0.1)

PRODUCT

MACHINE

CAP.

GET

MAX PRESSURE

SERIAL

WT.

WLL.

www.wedgelockusa.com          Made in USA

EXAMPLE

NORTH AMERICA

Содержание I-LOCK

Страница 1: ...THIS OPERATORS MANUAL MUST BE KEPT WITH THE CARRIER MACHINE AT ALL TIMES Toll free 800 CASCADE 227 2233 Telephone 503 669 6257 cascadewedgelock cascorp com NORTH AMERICA...

Страница 2: ......

Страница 3: ...SECOND PIN 7 2 3 TO DISENGAGE THE FIRST PIN 7 2 4 READY TO RE CONNECT 8 2 5 NORMAL OPERATING PROCEDURE FLOW DIAGRAM 9 SECTION 3 MAINTENANCE 3 0 COUPLER IDENTIFICATION 10 3 1 SERVICING SCHEDULE SECTIO...

Страница 4: ...ith the I LOCKTM SAFETY SYSTEM which ensures that your attachment is locked the INSTANT that it is latched see figure 1 0 1 This means there is no danger of dropping the attachment if the primary lock...

Страница 5: ...oupler body minimizing the wear in the locking area of your coupler 1 1 INTEGRATED DESIGN FEATURES Integral with the solenoid operated directional control valve are 2 pressure reducers set to Locking...

Страница 6: ...inkage mechanism while the hydraulic system is pressurized or the carrier machine is turned on Never use the Primary Locking Wedge or I LOCK Safety Knuckle as a lifting device FOR INFORMATION RELATING...

Страница 7: ...pin of the attachment Fig 2 0 3 2 1 CONNECTING TO THE SECOND PIN Rear Pin Operator Action Using the excavator arm control levers simultaneously lift and crowd the attachment until the second pin rear...

Страница 8: ...d from the rear jaw 2 3 TO DISENGAGE THE FIRST PIN Front Pin Operator Action Depress the Momentary Switch for more than one second to activate the release of the Safety Knuckle Using the excavator arm...

Страница 9: ...ng of the Safety Knuckle is controlled by a timer factory set at 10 seconds To adjust the timer refer to 2 5 Normal Operating Procedure Flow Diagram 2 4 READY TO RE CONNECT NOTE Please read carefully...

Страница 10: ...1 second Remove Attachment 5 10 second window Safety Resets Automatically Connect Attachment Turn Power OFF using LOCK OUT SWITCH Wedge extends Timer Adjustment Power Off Press and hold MOMENTARY SWIT...

Страница 11: ...ly Weekly Check all pin retainers bolts nuts for tightness on the quick coupler and the attachments Lubricate all greaseing points the attachment will have to be removed to access all grease points Ch...

Страница 12: ...2 I Lock Safety Knuckle remains in retracted up position Check Safety Knuckle housing for damage Repair or replace parts if necessary Check Safety Knuckle and housing for lodged debris Remove debris C...

Страница 13: ...ng pressure that extends the Primary Wedge Adjust the pressure reducing valve if required Check the inlet port on coupler directional control valve Clean and clear any debris that is present from the...

Страница 14: ...and verify the safe working load of the coupler lifting eye by referring to the coupler aluminum data plate affixed to the coupler body 4 Ensure that you use the correct lifting rigs and lifting proce...

Страница 15: ...lic kits used in Cascade Corporation products but not manufactured directly by it Failure to follow Cascade Corporation s or the third party manufacturer s recommendations for oil pressure and flow ra...

Страница 16: ...e a third party is engaged to carry out repair work in connection with a Cascade Corporation warranty claim Cascade Corporation s obligation and liability shall be limited to a refund of the authorize...

Страница 17: ...cascorp com INSTALLER TO COMPLETE I acknowledge that I have read and understood the Installation Operator Manuals MAKE AND MODEL OF CARRIER MACHINE DATE OF INSTALLATION DD MM YY PRODUCT SERIAL NUMBER...

Страница 18: ...294 0187 USA 800 CASCADE 227 2233 Tel 503 669 6257 www wedgelockusa com Cascade and Wedgelock are registered trademarks of Cascade Corporation Cascade Corporation 2013 All rights reserved Form 6827659...

Отзывы: