6.7 Q and A´s
Problem
Reason / Remedy
The vacuum does not pump or move
1. Fuse broken/ Replace fuse
2. GFCI, EFCB or RCD has shut off the
power.
3.Over current relay has released
and not reset/Reset the relay
4.Impeller blocked. Release obstacle
5.Contactor burnt/ Replace.
6.Stator burnt/ Replace
The over current relay shuts off
1.Impeller blocked / remove obstacle.
2.Incorrect power feed/ Check
incoming voltage.
3.Stator burnt./ Replace
4.Water in the pump motor.
/Empty and dry off.
5.Motor overloaded./Check
for possible reasons.
The pump motor runs but the vacuum
will not move.
1.Make sure that the radio remote control
is not broken.
2.The DC converter is broken./ Replace
3. The clutches are sliding./Clean them off
and check the sealing.
The vacuum turns poorly
1 Drive track tension needs to be adjusted
2.Oil or water on the magnetic clutches/
Clean them off and check the sealing.
The vacuum only moves in one direction
and/or it stops when it reaches a wall or
any other obstacle.
1. Defect or incorrectly adjusted sensors/
Check and make corrections.
2. Sensors broken/Replace sensors