background image

?

!

WEDA W

50 

R

6.7   Q and A´s

Problem  

 

 

 

 

 

                 Reason / Remedy 

The vacuum does not pump or move 

 

 

 

1. Fuse broken/ Replace fuse

 

 

 

 

 

 

 

 

2. GFCI, EFCB or RCD has shut off the  

 

 

 

 

 

 

 

 

 

   power.

 

 

 

 

 

 

 

 

3.Over current relay has released 

 

 

 

 

 

 

 

 

    and not reset/Reset the relay

 

 

 

 

 

 

 

 

4.Impeller blocked. Release obstacle

 

 

 

 

 

 

 

 

5.Contactor burnt/ Replace.

 

 

 

 

 

 

 

 

6.Stator burnt/ Replace

The over current relay shuts off 

 

 

 

 

1.Impeller blocked / remove obstacle.

 

 

 

 

 

 

 

 

2.Incorrect power feed/ Check 

 

 

 

 

 

 

 

 

   incoming voltage. 

 

 

 

 

 

 

 

 

 

 

 

3.Stator burnt./ Replace

 

 

 

 

 

 

 

 

4.Water in the pump motor.  

 

 

 

 

 

 

 

 

   /Empty and dry off.

 

 

 

 

 

 

 

 

5.Motor overloaded./Check 

 

 

 

 

 

 

 

 

   for possible reasons.

The pump motor runs but the vacuum  
will not move.   

 

 

 

 

 

1.Make sure that the radio remote control  

 

 

 

 

 

 

 

 

   is not broken.

 

 

 

 

 

 

 

 

2.The DC converter is broken./ Replace

 

 

 

 

 

 

 

 

3. The clutches are sliding./Clean them off  

 

 

 

 

 

 

 

 

    and check the sealing.

The vacuum turns poorly   

 

 

 

                 1 Drive track tension needs to be adjusted

 

 

 

 

 

 

 

 

2.Oil or water on the magnetic clutches/    

 

 

 

 

 

 

 

 

   Clean them off and check the sealing.

The vacuum only moves in one direction 
and/or it stops when it reaches a wall or
any other obstacle. 

 

 

 

 

 

1. Defect or incorrectly adjusted sensors/    

 

 

 

 

 

 

 

                     Check and make corrections.

 

 

 

 

 

 

 

 

2. Sensors broken/Replace sensors

Содержание W50 R

Страница 1: ...OPERATINGMANUAL EDITION 1 WEDA W50 R 32 utg 3 20091007 110 V 230 V 60Hz 230 V 50Hz...

Страница 2: ...ble of Content 1 Weda Poolcleaner AB and Pool Vacuums 2 Delivery specifications 3 Technical specifications 4 Installation 5 Operating Instructions 6 Service and Maintenance 7 Control Box and Electrica...

Страница 3: ...decrease the usage of chlorine in pools Weda strives to design better and more flexible pool vacuums so that we can optimize the vacuum for each pool and meet the customers high demands The latest pr...

Страница 4: ...X 300 mm Weight in air 62 lbs 28 kg Weight in water 26 lbs 12 kg Cleaning width 20 inches 500 mm Maximum suction capacity 150 Gallons min 600 l mn Speed 0 6 Feet Second 0 2 m s Maximum Water temperatu...

Страница 5: ...cting to power make sure that the wall outlet has The correct voltage The correct fuses The correct frequency 60 Hz and A GFCI or ELCB or RCD with correct setting see above The power supply cable the...

Страница 6: ...ns Switch On Off with light Switch Manual automatic On the bottom of the control box you find The power cable connection Connect via a GFCI or ELCB or RCD Reset for the over current protection Reset b...

Страница 7: ...box is used leave the Trolley at a minimum of 2 meters 7 ft from the edge of the pool Check any local regulations that may apply Roll out the floating cable umbilical and stretch it out as straight as...

Страница 8: ...nsors in combination with built in timers 5 6 Recovering the W50 from the pool Switch to manual mode on the control box Drive the vacuum towards the wall where it will be taken out of the pool Put dow...

Страница 9: ...y 200 hours Greasing of the shaft seal For vacuums working no deeper than 5 meters 15 ft depths the shaft seal should be greased after every 200 hours of cleaning Use only food approved white grease W...

Страница 10: ...s and belts Loosen the domed nuts 12 and lift off the covers 11 Loosen the wheel bolts 4 the track tension bolts 9 and 10 and the front shaft 8 Pull off the wheels and the tracks Now the belts and the...

Страница 11: ...iest way to do this is to run the vacuum in circles in the pool Always disconnect the vacuum from the outlet before making any service and maintenance The control box being 110 230 V may only be servi...

Страница 12: ...Water in the pump motor Empty and dry off 5 Motor overloaded Check for possible reasons The pump motor runs but the vacuum will not move 1 Make sure that the radio remote control is not broken 2 The D...