Tab. 4 - Parameters of the 1st level Menu in TIG DC PULSED mode.
LED
SETTING
MIN
DEFAULT
MAX
NOTES
L2
PRE-GAS TIME
0.0 s
0.0 s
3.0 s
-
STARTING CURRENT
-
-
-
Set by the manufacturer. Not user-adjust
-
able. Not displayed.
L3
SLOPE UP
0.0 s
0.0 s
20.0 s
L5
WELDING CURRENT
5 A
80 A
160 A
L4
PULSED CURRENT FREQUENCY
0.5 Hz
125 Hz
500 Hz
L6
DOWN SLOPE
0.0 s
0.0 s
20.0 s
L7
FINAL CURRENT
5 A
5 A
160 A
L8
POST GAS TIME
0.0 s
3.0 s
25.0 s
Tab. 5 - Parameters of the 1st level Menu in TIG DC SYNERGIC PULSED mode.
LED
SETTING
MIN
DEFAULT
MAX
NOTES
L2
PRE-GAS TIME
0.0 s
0.0 s
3.0 s
-
STARTING CURRENT
-
-
-
Set by the manufacturer. Not user-adjust
-
able. Not displayed.
This parameter is set as a percentage
referred to the value of the following
parameter: WELDING CURRENT
L3
SLOPE UP
0.0 s
0.0 s
20.0 s
L5
WELDING CURRENT
5 A
80 A
160 A
L4
PULSED CURRENT FREQUENCY
0.5 Hz
125 Hz
500 Hz
L6
DOWN SLOPE
0.0 s
0.0 s
20.0 s
L7
FINAL CURRENT
5 A
5 A
160 A
L8
POST GAS TIME
0.0 s
3.0 s
25.0 s
WELDING CURRENT
Output current value during welding.
PRE-GAS TIME
Time of gas delivery before the arc strike.
This adjustment is required when fixing points must be created or when welding in hard-to-reach posi
-
tions that call for the presence of inert atmospheres before striking the arc.
Consequences of a higher value:
-
This parameter allows a shielded environment to be created, thereby eliminating contaminants
at the start of the welding pass.
STARTING CURRENT
Unit current output value immediately after the arc strike.