General Specification for all models

Ambient temperature:  5 to 40°C (41 - 104°F)

Fluid type

Mineral oil to ISO 11158 category HM 

 

(for other fluid types please contact Sales).

Fluid temperature

DHT & HT - 0 to 120°C (32 - 250°F)

 

DHM - 0 to 105°C (32 - 220°F)

Accuracy

see model specifications

EMC Environment

This equipment is intended for use within industrial and residential 

environments and does not suffer any degradation in operation when 

subjected to test conditions according to requisite standards.

Construction materials

Case

Painted mild steel

Flow block

High tensile aluminium

Seals

FKM as standard - EPDM seals on request

Battery Details

PP3 9 volt Alkaline (IEC6LR61, ANSI/NEDA 1604A)

Dimensions and Weight

 Model 

Height 

Width 

Depth 

Weight

 DHT401

  HT302/402 

200 mm 

240 mm 

200 mm 

6.5 kg

  DHT302/402 

7.87 inches 

9.45 inches  

7.87 inches 

14.33 lbs

 DHM404
 DHT801

  HT602/802 

225 mm 

245 mm 

225 mm 

10 kg

  DHT602/802 

8.86 inches 

9.65 inches 

8.86 inches 

22 lbs

 DHM804

Fluid viscosity

The performance of the tester can be affected by the viscosity of the fluid measured. Our testers 

are calibrated at a mean viscosity of 21 cSt using ISO32 hydraulic mineral oil to ISO11158 

category HM. The shaded area of the table shows the range of viscosities that can be measured 

by a tester with standard calibration with minimal effect on the accuracy (less that ± 1% FS).

Table showing kinematic viscosity (cSt) of different mineral 

oils at specific temperatures

 

Fluid type

 

  Temp °C 

ISO15 ISO22  ISO32 ISO37 ISO46  ISO68

 

 0 

85.9  165.6  309.3  449.9  527.6  894.3

  10 

49.0  87.0  150.8 204.7 244.9  393.3

  20 

30.4  50.5  82.2  105.5 127.9 196.1

 30 

20.1  31.6  48.8  59.8  73.1  107.7

 40 

14.0  21.0  31.0  36.6  44.9  63.9

 50 

10.2  14.7  20.8  23.9  29.4  40.5

 60 

7.7  10.7  14.7  16.5  20.2  27.2

 70 

6.0  8.1  10.9  12.0  14.6  19.2

 80 

4.8  6.4  8.4  9.1  11.1  14.3

 90 

4.0  5.2  6.6  7.2  8.7  11.1

 100 

3.3  4.3  5.5  6.0  7.1  8.9

ISO 15, 22, 32, 46 and 68 based on typical figures for the Esso Nuto range of 

HM oils. ISO 37 based on Shell Tellus HM oil.

Содержание DHT401

Страница 1: ...raulic Testers User Manual Bedienungsanleitung f r tragbare Hydraulik Testger te der Reihen 1 2 und 4 Manuel d utilisation des Testeurs Hydrauliques portables des s ries 1 2 4 Manual de usuario de los...

Страница 2: ...and receiver l Connect the equipment into an outlet on a circuit different from that to which the receiver is connected l Consult the dealer or an experienced radio TV technician for help Canada This...

Страница 3: ...Series Digital Hydraulic Multimeter There are different sizes and porting options to cover a wide range of flows This manual covers all testers Before first operating the equipment read the whole of t...

Страница 4: ...trol in both directions of flow The loading valve has two easily replaceable safety discs located in the valve assembly which internally protect the tester and machine in both flow directions Installa...

Страница 5: ...ne and adjust the loading valve as needed 9 When the test is completed fully open loading valve Notes When low pressure testing is required connect the optional low pressure gauge with automatic cut o...

Страница 6: ...mm 10 kg DHT602 802 8 86 inches 9 65 inches 8 86 inches 22 lbs DHM804 Fluid viscosity The performance of the tester can be affected by the viscosity of the fluid measured Our testers are calibrated a...

Страница 7: ...gpm Fahrenheit Flow Accuracy 1 of full scale Pressure Accuracy 1 6 of full scale Temperature Accuracy 1 C 2 F per J518 SAE Code 61 standard Model Number Flow Range gpm Pressure Range psi Inlet Outlet...

Страница 8: ...nfra red phototachometer l Selector switch Turn the switch to select the required function l OFF RESET Switches the tester off and resets the unit after automatic power shut off l B TEST Checks the co...

Страница 9: ...peed Needs optional infra red phototachometer using one or more retro reflective marks Range See Table Accuracy 2 of full scale per J518 SAE Code 61 standard Model Flow Flow Scales Pressure Speed Inle...

Страница 10: ...n socket for the optional infra red phototachometer l External flow Connection socket for optional second LT series flow meter to measure a second flow and temperature l Selector switch Turn the switc...

Страница 11: ...Mode EXT INT and TACH External Flow EXT 1 Turn selector switch to Ext Flow 2 Press C F button and hold down Then press ON i e two buttons are pressed at the same time 3 On the left side of the display...

Страница 12: ...Q Pressing this button will change the bottom line of the display from temperature to power This button is also used to start the efficiency display on screen 3 l Clear peak Press to clear the peak pr...

Страница 13: ...from the flow and pressure the hydraulic power is displayed in either HP or KW The engineering units for power are linked to the pressure units and can be changed using the pressure units button on th...

Страница 14: ...igital Screen 2 Analogue Screen 3 P Q Bar graph scaling EU US DHM404 DHM804 DHM404 DHM804 Flow LPM 0 400 0 800 GPM 0 100 0 210 Pressure BAR 0 600 0 600 PSI 0 8700 0 8700 Peak BAR 0 600 0 600 PSI 0 870...

Страница 15: ...ure display between power and temperature When the meter is turned ON the contrast buttons can be used to adjust the display to suite the ambient light conditions Settings are saved Pressing the clear...

Страница 16: ...ted by the soft menu keys designated on the bottom line Clear peaks button becomes the scroll UP key Pressure unit s button becomes the scroll DWN key PQ HP button becomes the DEL key The soft menu ac...

Страница 17: ...machine For 2 series testers only Infrared photo tachometer comprises infrared photo tach head six metre connecting cable and reflective tape The BA20 magnetic base with flexible arm is also available...

Страница 18: ...i que les autres obligations et responsabilit s Aucun agent revendeur ou distributeur en aucun cas n a le pouvoir ou l autorit de modifier les termes de cette garantie F nf Jahre begrenzte Garantie de...

Страница 19: ...previo aviso For Sales Service contact Auskunft Beratung Contact Service commercial maintenance Para m s informaci n sobre ventas y servicios contactar con Distributor Vertriebspartner Distributeur D...

Отзывы: