General Operation

All tests should be performed by suitably qualified personnel. 

1. Connect the Tester to the circuit (see above for installation guidance) 

2. Ensure that the pressure loading valve is fully opened by turning the knob counter clockwise.

3. Switch the unit on. On digital models if the display flashes, or on analogue models if the 

needle points to the symbol, then the battery needs replacing.

4. Select the desired test using the front panel controls where applicable.

5. IMPORTANT: Ensure that all connections are tightened and the oil can flow freely throughout 

the hydraulic system BEFORE running the machine at full speed. Check that the circuit is 

correctly connected and any shut-off valves are opened. Also quick disconnect couplers 

MUST be open.

6. Start the pump momentarily to ensure there is no obstruction which could cause pressure 

build up.

7. Check for leaks and free flow of oil

8. The tester is now ready for use - run the machine and adjust the loading valve as needed

9. When the test is completed fully open loading valve. 

Notes

When low pressure testing is required, connect the optional low pressure gauge with automatic 

cut-out valve to the tester block.

Testers have an automatic electronic system which shuts the power off after approximately 

20 minutes should you forget. To reactivate the tester, turn the selector switch to the “OFF / 

RESET” position then back to ‘ON’.

Performance

All 600 & 800 models have limited pressure control below 86 lpm (23 USgpm). The maximum 

controllable pressure in this region is calculated by: Max. pressure (in bar) = 5 x flow (lpm) +30.

Do not use with water

The standard Webtec Hydraulic Testers are designed for use with mineral oil having reasonable 

lubrication properties. They are not suitable for use with water or fluids with a high water 

content. If a tester is contaminated with water it should be flushed immediately with white or 

methylated spirit or similar and then flushed with mineral oil to minimise any internal corrosion. 

This may avoid an expensive repair. Damage to a tester from the use of a non-approved fluid 

invalidates our normal warranty.

Содержание DHT401

Страница 1: ...raulic Testers User Manual Bedienungsanleitung f r tragbare Hydraulik Testger te der Reihen 1 2 und 4 Manuel d utilisation des Testeurs Hydrauliques portables des s ries 1 2 4 Manual de usuario de los...

Страница 2: ...and receiver l Connect the equipment into an outlet on a circuit different from that to which the receiver is connected l Consult the dealer or an experienced radio TV technician for help Canada This...

Страница 3: ...Series Digital Hydraulic Multimeter There are different sizes and porting options to cover a wide range of flows This manual covers all testers Before first operating the equipment read the whole of t...

Страница 4: ...trol in both directions of flow The loading valve has two easily replaceable safety discs located in the valve assembly which internally protect the tester and machine in both flow directions Installa...

Страница 5: ...ne and adjust the loading valve as needed 9 When the test is completed fully open loading valve Notes When low pressure testing is required connect the optional low pressure gauge with automatic cut o...

Страница 6: ...mm 10 kg DHT602 802 8 86 inches 9 65 inches 8 86 inches 22 lbs DHM804 Fluid viscosity The performance of the tester can be affected by the viscosity of the fluid measured Our testers are calibrated a...

Страница 7: ...gpm Fahrenheit Flow Accuracy 1 of full scale Pressure Accuracy 1 6 of full scale Temperature Accuracy 1 C 2 F per J518 SAE Code 61 standard Model Number Flow Range gpm Pressure Range psi Inlet Outlet...

Страница 8: ...nfra red phototachometer l Selector switch Turn the switch to select the required function l OFF RESET Switches the tester off and resets the unit after automatic power shut off l B TEST Checks the co...

Страница 9: ...peed Needs optional infra red phototachometer using one or more retro reflective marks Range See Table Accuracy 2 of full scale per J518 SAE Code 61 standard Model Flow Flow Scales Pressure Speed Inle...

Страница 10: ...n socket for the optional infra red phototachometer l External flow Connection socket for optional second LT series flow meter to measure a second flow and temperature l Selector switch Turn the switc...

Страница 11: ...Mode EXT INT and TACH External Flow EXT 1 Turn selector switch to Ext Flow 2 Press C F button and hold down Then press ON i e two buttons are pressed at the same time 3 On the left side of the display...

Страница 12: ...Q Pressing this button will change the bottom line of the display from temperature to power This button is also used to start the efficiency display on screen 3 l Clear peak Press to clear the peak pr...

Страница 13: ...from the flow and pressure the hydraulic power is displayed in either HP or KW The engineering units for power are linked to the pressure units and can be changed using the pressure units button on th...

Страница 14: ...igital Screen 2 Analogue Screen 3 P Q Bar graph scaling EU US DHM404 DHM804 DHM404 DHM804 Flow LPM 0 400 0 800 GPM 0 100 0 210 Pressure BAR 0 600 0 600 PSI 0 8700 0 8700 Peak BAR 0 600 0 600 PSI 0 870...

Страница 15: ...ure display between power and temperature When the meter is turned ON the contrast buttons can be used to adjust the display to suite the ambient light conditions Settings are saved Pressing the clear...

Страница 16: ...ted by the soft menu keys designated on the bottom line Clear peaks button becomes the scroll UP key Pressure unit s button becomes the scroll DWN key PQ HP button becomes the DEL key The soft menu ac...

Страница 17: ...machine For 2 series testers only Infrared photo tachometer comprises infrared photo tach head six metre connecting cable and reflective tape The BA20 magnetic base with flexible arm is also available...

Страница 18: ...i que les autres obligations et responsabilit s Aucun agent revendeur ou distributeur en aucun cas n a le pouvoir ou l autorit de modifier les termes de cette garantie F nf Jahre begrenzte Garantie de...

Страница 19: ...previo aviso For Sales Service contact Auskunft Beratung Contact Service commercial maintenance Para m s informaci n sobre ventas y servicios contactar con Distributor Vertriebspartner Distributeur D...

Отзывы: