VENTILATION
WARNING: Air holes must be provided in the structure at the
top and bottom to provide ventilation in the event of a gas leak.
Air holes can be located in a low visibility area and should be protected by screening
material to prevent rodents and insects from entering the structure. Air holes will also help
dry moisture.
Summit
®
Built-In cabinet vents are available from your dealer or call Customer Service at
1-800-446-1071.
Note: These drawings are only a reference.
•
Cross ventilation must be incorporated in the supporting structure. We recommend
a minimum of 100 square inches (254 square cm )of venting per side.
•
Vents should be on two sides of the structure.
•
The above drawings are for reference only.
•
Location of the vents should be from the center, outward.
•
Locate the vents at both the bottom of the structure and at the top of the structure.
•
The bottom vents should be as close to ground level as possible. Make sure the
vent area is not blocked by interior supports of the structure.
•
We recommend vents with screens.
•
Access doors to the structure are not considered vents.
•
Clean the vents periodically.
DANGER: Failure to follow recommended minimum venting
instructions can cause gas to collect in the structure in the
event of a gas leak. This may result in a fi re or an explosion
which can cause serious bodily injury or death, and damage to
property.
ATTENTION: This product has been safety tested and
is only certifi ed for use in a specifi c country. Refer to
country designation located on outer carton.
These parts may be gas carrying or gas burning components. Please
contact Weber-Stephen Products Co., Customer Service Department
for genuine Weber-Stephen Products Co. replacement part(s)
information.
WARNING: Do not attempt to make any repair to
gas carrying or gas burning components without
contacting Weber-Stephen Products Co., Customer
Service Department. Your actions, if you fail to follow
this product Warning, may cause a fi re or an explosion
resulting in serious personal injury or death and
damage to property.
GAS SUPPLY
Содержание Summit S-440
Страница 8: ...8 WWW WEBER COM 5 6 Back ASSEMBLY...
Страница 9: ...9 WWW WEBER COM 9 7 ASSEMBLY...
Страница 12: ...12 WWW WEBER COM F S440 11 1 3 2 12 ASSEMBLY...
Страница 13: ...13 WWW WEBER COM 13 S640 S440 13 14 1 2 S640 S440 ASSEMBLY...
Страница 14: ...14 WWW WEBER COM S640 S440 a b c 15 Match Holder ASSEMBLY...
Страница 15: ...15 WWW WEBER COM 15 S640 S440 16 17 1 4 6 35 mm Drill Bit ASSEMBLY...
Страница 16: ...16 WWW WEBER COM S640 S440 18 19 20 S440 S640 S640 S440 ASSEMBLY...
Страница 17: ...17 WWW WEBER COM 17 ASSEMBLY 21 S640 S440...
Страница 18: ...18 WWW WEBER COM 1 2 3 22 S 440 S 640 ASSEMBLY...