VEnTILATIon

m

  wArnInG: Ventilation holes must be provided in the 

structure at the top and bottom to provide ventilation in the 
event of a gas leak.

Ventilation holes can be located in a low visibility area and should be protected by 
screening material to prevent rodents and insects from entering the structure. Air holes 
will also help dry moisture.

Note: These drawings are only a reference.

•  Cross ventilation must be incorporated in the supporting structure. We recommend a 

minimum of 100 square inches (254 square cm) of venting per side.

•  Vents should be on two sides of the structure. 
•  The drawings are for reference only.
•  Location of the vents should be from the center, outward.
•  Locate the vents at both the bottom of the structure and at the top of the structure.
•  The bottom vents should be as close to ground level as possible. Make sure the vent 

area is not blocked by interior supports of the structure.

•  We recommend vents with screens.
•  Access doors to the structure are not considered vents.
•  Clean the vents periodically.

bUILT-IN TANK eNcLoSURe ASSembLY VeNTILATIoN

m

 dAnGEr

failure to follow recommended minimum venting 
instructions can cause gas to collect in the structure in the 
event of a gas leak. This may result in a fire or an explosion 
which can cause serious bodily injury or death, and damage 
to property. 

m

  ATTEnTIon: This product has been safety tested and is only certified for use in a specific country. refer to country 

designation located on outer carton. 

These parts may be gas carrying or gas burning components. Please contact Weber-Stephen Products LLC Customer Service 
Department for genuine Weber-Stephen Products LLC replacement part(s) information.

m

  wArnInG: do not attempt to make any repair to gas carrying, gas burning, igniter components or structural components 

without contacting weber-stephen Products LLC Customer service department. Your actions, if you fail to follow this 
Product warning, may cause a fire, an explosion, or structural failure resulting in serious personal injury or death as well as 
damage to property.

WEBER-STEPHEN PRODUCTS LLC

www.weber.com

®

© 2011 Designed and engineered by Weber-Stephen Products LLC 

a Delaware limited liability company, located at 200 East Daniels Road, Palatine, Illinois 60067 U.S.A. 

Printed in U.S.A.

Содержание Summit 460-LPG

Страница 1: ... which can cause serious bodily injury or death or damage to property m WARNING 1 Do not store spare LPG cylinder within 10 feet 3m of this appliance 2 Do not store or use petrol or other flammable liquids or vapors within 25 feet 8m of this appliance m WARNING Follow all leak check procedures carefully in this manual prior to barbecue operation Do this even if the barbecue was dealer assembled NO...

Страница 2: ...ill installation give attention to concerns such as exposure to wind proximity to traffic paths and keeping any gas supply lines as short as possible Never locate the Summit gas grill in a garage breezeway shed under an unprotected overhang or other enclosed area Locate the grill and structure so there is enough room to safely evacuate the area in case of a fire CLEARANCE FROM SURFACES OR STRUCTUR...

Страница 3: ...and heaving Rotisserie Outlet If the supporting structure is going to have an electrical outlet for a rotisserie it should be on the left side of the structure 1 The barbecue illustrated may have slight differences to the model purchased BUILT IN CUTOUT DETAILED DIMENSIONS 2 3 5 6 7 a b c b 1 2 3 1 1 460 660 DIMENSIONS 1 24 minimum 610 mm 24 minimum 610 mm 2 16 1 2 419 mm 16 1 2 419 mm 3 11 1 8 28...

Страница 4: ...or hose located inside the tank enclosure 2 C Connect the main corrugated hose to the 90 bulkhead fitting Use the 1 2 12 7 mm flared gasket to ensure proper seal 3 Note 1 2 flared gaskets are included in the Summit Built In tank Enclosure Kit included with your grill CONNECTION CHART 1 2 3 4 5 6 7 8 9 10 4 Typical tank cabinet or tank enclosure location 5 Side view 6 Top of box 7 Back of box 8 Cor...

Страница 5: ...TANK ENCLOSURE ASSEMBLY VENTILATION m DANGER Failure to follow recommended minimum venting instructions can cause gas to collect in the structure in the event of a gas leak This may result in a fire or an explosion which can cause serious bodily injury or death and damage to property m ATTENTION This product has been safety tested and is only certified for use in a specific country Refer to countr...

Отзывы: