background image

C-5

Gas  Instructions

Safe handling tips for Liquid Propane
Gas Cylinders

  Liquid Propane (LP) gas is a petroleum product as are

gasoline and natural gas. LP gas is a gas at regular
temperatures and pressures. Under moderate pressure,
inside a cylinder, LP gas is a liquid. As the pressure is
released, the liquid readily vaporizes and becomes gas.

  LP gas has an odor similar to natural gas. You should

be aware of this odor.

  LP gas is heavier than air. Leaking LP gas may collect

in low areas and prevent dispersion.

  To fill, take the LP cylinder to an RV center, or look up

“gas-propane” in the phone book for other sources of
LP gas.

 

WARNING: We recommend that your LP cylinder be

filled at an authorized LP gas dealer, by a qualified
attendant, who fills the tank by weight. IMPROPER
FILLING IS DANGEROUS.

 

WARNING: If you exchange your LP cylinder, make

sure you get a similar tank in return. Your LP
cylinder is equipped with a quick closing coupling
or type 1 valve and an OPD (Overfilling Prevention
Device). Other LP cylinders may not be compatible
with your barbecue connection.

  Air must be removed from a new LP cylinder before the

initial filling. Your LP dealer is equipped to do this.

  The LP cylinder must be installed, transported and

stored in an upright position. LP cylinders should not be
dropped or handled roughly.

  Never store or transport the LP cylinder where

temperatures can reach 125° F (too hot to hold by hand
- for example: do not leave the LP cylinder in a car on a
hot day).

Note - A refill will last about 20 hours of cooking time at
normal use. The fuel scale will indicate the propane supply
so you can refill before running out. You do not have to run
out before you refill.

  Treat “empty” LP cylinders with the same care as when

full. Even when the LP tank is empty of liquid there still
may be gas pressure in the cylinder. 

Always close the

cylinder valve before disconnecting.

 

CAUTION: When transporting the LP cylinder make

sure the plastic dust cover is in place over the
valve. This will keep dust and dirt from the threaded
portion of the valve.

  Do not use a damaged LP cylinder. Dented or rusty LP

cylinders or LP cylinders with a damaged valve may be
hazardous and should be replaced with a new one
immediately.

Liquid Propane (LP) Cylinder(s)

The joint where the hose connects to the LP cylinder
must be leak tested each time the LP cylinder is
reconnected. For example, test each time the LP
cylinder is refilled.

  Be sure the regulator is mounted with the small vent

hole pointed downward so that it will not collect water.
This vent should be free of dirt, grease, bugs etc.

The LP cylinder and connections supplied with your
Weber

®

 gas barbecue have been designed and tested

to meet government, American Gas Association, and
Underwriters Laboratories requirements.

Liquid Propane Cylinder requirements

  Replacement LP cylinders supplied by Weber satisfy

the above requirements. Check to be sure other
cylinders have a D.O.T. certification(1), and date
tested(2) is within five years. Your LP gas supplier can
do this for you.

If you have questions about spare LP cylinders
contact the Customer Service Representative in your
region using the contact information sheet provided
with your manual.

All LP tank supply systems must include a collar to
protect the cylinder valve.

The LP cylinder must be a 20-lb. size (18 1/4 inches
high, 12 1/4 inches in diameter).

The LP cylinder must be constructed and marked in
accordance with the specifications for LP gas cylinders
of the U.S. Department of Transportation (D.O.T.).

For Canada Only

Liquid Propane Cylinder requirements

 WARNING: Replacement LP tanks must match the

regulator connection supplied with this barbecue.

Note: Your retailer can help you match a replacement tank
to your barbecue

All LP tank supply systems must include a collar to
protect the cylinder valve.

The LP cylinder must be a 20-lb. size (18 1/4 inches
high, 12 1/4 inches in diameter).

The LP cylinder must be constructed and marked in
accordance with the specifications for LP gas cylinders,
T.C.

DOT 4BA240

 

00/01

(1)

(2)

Содержание GENESIS GOLD C

Страница 1: ...ble liquids or vapors within 25 feet 8m of this appliance DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flames 3 Open lid 4 If odor continues keep away from the applian...

Страница 2: ...Do not use charcoal or lava rock in your Weber gas barbecue Never lean over open grill or place hands or fingers on the front edge of the cooking box Should a grease fire occur turn off all burners an...

Страница 3: ...0 Assembly Instructions B a Gas Instructions C 1 Leak Checking C 3 Refilling the LP Cylinder C 4 Safe handling tips for LP Gas C 5 Operating D 1 Lighting D 1 Manual Lighting D 2 Lighting the side burn...

Страница 4: ...here is not covered by this Limited Warranty Aluminum Castings lifetime 1 year paint Stainless Steel Hood Section 25 years Burners 10 years Igniter 3 years Cooking Grates 7 years no rust through Flavo...

Страница 5: ...of this appliance must comply with local codes and or Standard CAN CGA B149 2 Installation Code for Propane Burning Appliances and Equipment Operating WARNING Only use this barbecue outdoors in a wel...

Страница 6: ...efore each use Remove excess grease to avoid a grease fire in the slide out bottom tray Cleaning WARNING Turn your Weber gas barbecue OFF and wait for it to cool before cleaning CAUTION Do not clean y...

Страница 7: ...A 7 ExplodedView Genesis Gold C LP 111301 5 1 2 3 4 6 7 8 9 10 11 12 13 16 17 20 21 22 23 24 25 26 27 28 29 30 32 33 34 35 36 37 38 39 40 41 42 43 44 45 34 46 47 49 50 52 53 54 18 19 31 15 14 48 55 51...

Страница 8: ...23 Caster Frame 24 Caster 25 Bottom Rack 26 Wheel 27 Hubcap 28 Hair Pin Cotter 29 Right Endcap 30 Thermometer 31 Handle Hardware 32 Control Panel Knobs 33 Control Panel 34 Control Panel Hardware 35 C...

Страница 9: ...able 1 Side Table 1 Flavorizer Bars 5 Warm Up Basket 1 Warming Rack 1 LP Tank 1 Bottom Tray 1 Catch Pan Holder 1 Catch Pan 1 Disposable Drip Pans 2 Thermometer 1 1 inch Bolts 1 4 x 20 x 1 inch Bolt 8...

Страница 10: ...A 10 1 2 3 4 Unpacking...

Страница 11: ...B a 1 Push down firmly until Bottom Rack Lock locks under the rail Arrow sticker to the front b c a Ba202 d...

Страница 12: ...B b Push down firmly on both sides to ensure bottom rack is locked under the rails WARNING Do not go to next step if bottom rack is not locked in place 2 a b...

Страница 13: ...B c 3 Install bolts at indicated locations Use supplied tool to tighten Finish tightening bolt with metal wrench provided or a 7 16 wrench...

Страница 14: ...B 1 4 B204_LP b...

Страница 15: ...B 2...

Страница 16: ...B 3 5 6...

Страница 17: ...B 4 a b 7 c...

Страница 18: ...B 5 a b 8 10 9...

Страница 19: ...B 6 b a 12 13 11...

Страница 20: ...B 7...

Страница 21: ...d damage to property Raises up while filling then stops when full Check that all burner valves are off Valves are shipped in the OFF position but you should check to be sure that they are turned OFF C...

Страница 22: ...he valve 4 Screw the regulator coupling onto the tank valve clockwise or to the right Hand tighten only Note This is a new type of connection It tightens clockwise and will not allow gas to flow unles...

Страница 23: ...as dealer or store assembled You will need a soap and water solution and a rag or brush to apply it Note Since some leak test solutions including soap and water may be slightly corrosive all connectio...

Страница 24: ...ls the cylinder by weight IMPROPER FILLING IS DANGEROUS CAUTION When transporting the LP cylinder make sure the plastic dust cover is in place over the valve This will keep dust and dirt from the thre...

Страница 25: ...cylinder make sure the plastic dust cover is in place over the valve This will keep dust and dirt from the threaded portion of the valve Do not use a damaged LP cylinder Dented or rusty LP cylinders o...

Страница 26: ...on the LP cylinder valve the excess gas flow control feature will activate limiting the flow of gas from the LP cylinder If this should occur turn OFF the LP cylinder valve and burner control knobs Th...

Страница 27: ...for the gas to clear before attempting to light the barbecue Failure to do so may result in an explosive flame up which can cause serious bodily injury or death 3 Turn the cylinder on by turning the...

Страница 28: ...Push down and turn the side burner control valve to HI 5 Push the side burner igniter button several times so it clicks each time CAUTION Side burner flame may be difficult to see on a bright sunny d...

Страница 29: ...er light with a match Refill LP cylinder Straighten fuel hose If you can light the Front burner with a match then check the Crossover Ignition System Experiencing flare ups CAUTION Do not line the bot...

Страница 30: ...checkigniter see below Side Burner maintenance WARNING All gas controls and supply valves should be in the OFF position Check igniter Remove side burner cover To remove side burner cover remove contro...

Страница 31: ...shutter is fitted with a stainless steel screen 1 to prevent spiders and other insects access to the burner tubes through the air shutter openings We recommend that you inspect the Spider Insect scree...

Страница 32: ...burners reverse 3 through 7 CAUTION The burner openings 1 must be positioned properly over the valve orifices 2 Check proper assembly before fastening manifold in place 1 WARNING After reinstalling th...