6 SRV
660
Prior to maintenance and repair work
Only use
original Weber spare parts
to ensure reliable and safe operation for maintenance or repair
work.
For repair, maintenance, or inspection work the engine of the tamper must be safeguarded against
unintentional starting.
All pressurized lines, particularly hydraulic lines and lines of the injection system of the drive motor
must be depressurized before performing maintenance or repair tasks.
For maintenance and repair tasks the tamper must be placed on a level and stable substrate and
must be secured from rolling off or tipping over.
Heavy components and subassemblies must be secured on hoisting machines with adequate bearing
capacity when they are replaced. Ensure that no hazard exists related to the raised components or
subassemblies.
Do not position yourself or work under suspended loads.
Operation under difficult conditions
Never inhale the exhaust gas; it contains carbon monoxide, a colorless and odorless gas that is
extremely hazardous, which if inhaled even briefly can cause unconsciousness and death.
Never operate the engines in enclosed areas or in areas that are poorly ventilated (tunnels, caves,
etc.) Exercise particular caution when operating the engine in the vicinity of people and livestock.
Adjusting tasks, maintenance tasks, and inspection tasks must be executed on schedule as specified
in this operating and maintenance manual. These activities should only be executed by instructed
personnel.
Operation
Prior to starting work the owner of the tamper must be familiar with the work environment. The work
environment includes obstacles in the work and traffic area, the bearing capacity of the ground, as
well as the necessary safeguarding of the construction site in the area adjacent to public traffic; and it
includes compliance with traffic regulations.
The tamper should only be operated when the protective fixtures are mounted. The protective fixtures
must all be in functional condition.
At least once per shift the tamper must be checked for apparent defects. If there are apparent defects
then operation of the tamper must be stopped immediately and the responsible person must be
informed. Prior to restarting, tamper malfunctions that have occurred must be corrected.
If lubricating oils and fuel come into contact with skin, they can cause skin cancer. Upon contact
with the skin, clean affected skin with suitable cleaning agent without delay.
Содержание SRV 660
Страница 2: ...2 SRV 660...
Страница 11: ...SRV 660 11 1Description 2 TYPE 3 Serial Number 4 Year of construction 5 Mass 6 Rated power KW 2 1 3 4 5 6...
Страница 21: ...SRV 660 21...
Страница 22: ...22 SRV 660...