Prior to starting work the owner of the interior concrete vibrator must be familiar with the work 

environment. The working environment includes obstacles in the work and traffic area, the bearing 

capacity of the ground, as well as the necessary safeguarding of the construction site.

The interior concrete vibrator should only be operated when the protective fixtures are mounted. 

The protective fixtures must all be in functional condition.

At least once per shift the interior concrete vibrator must be checked for apparent defects. If there are 

apparent defects then operation of the interior concrete vibrator must be stopped immediately and the 

responsible person must be informed. Prior to restarting, malfunctions of the interior concrete vibrator 

that have occurred must be corrected.

Maintenance

The power plug of the interior concrete vibrator must be unplugged prior to any repair work.

Repair work on electrical components may only be performed by a skilled worker.

When the repair work is complete, all protective fixtures must be reattached.

Discharged operating fluids must be collected and stored in suitable containers. Discharged  fluids 

must be appropriately disposed of in accordance with environmental protection regulations.

Changes and conversions

For safety reasons, do not make any unauthorized changes or conversions to the interior concrete 

vibrator. The manufacturer expressly excludes any liability for damage that occurs due to changes or 

conversions to the interior concrete vibrator. To ensure safe and reliable operation, only use original 

WEBER spare parts.

Содержание IVURplus 40

Страница 1: ...IVURplus 1 IVURplus 40 IVURplus 50 IVURplus 58 0242017 0243017 0244017 Operating and Maintenance Manual...

Страница 2: ...2 IVURplus...

Страница 3: ...s 5 Graphic presentation 9 Technical data 10 Transport 12 Activities prior to starting work 12 Electrical connection 12 Connecting the interior concrete vibrator to the converter 12 Initial operation...

Страница 4: ...nd maintenance manual you help avoid hazards reduce repair and downtime costs and increase the reliability and service life of your interior concrete vibrator This operating and maintenance manual mus...

Страница 5: ...ator is designed exclusively for compacting concrete Any other use of the interior concrete vibrator is considered to be improper use for which the owner shall be exclusively responsible All liability...

Страница 6: ...to discharge According to VDE regulation 0100 part 410 HD 384 4 41 and EC publication 384 4 41 electronic power sources are equated to safety isolating transformers if the cutoff in the event of a gr...

Страница 7: ...rmed Prior to restarting malfunctions of the interior concrete vibrator that have occurred must be corrected Maintenance The power plug of the interior concrete vibrator must be unplugged prior to any...

Страница 8: ...he typical value is 0 24 M Cleaning work Cleaning tasks should only be executed in areas that are suitable and have been approved for this purpose oil separator amongst others Disposal All operating f...

Страница 9: ...rall view IVURplus 40 50 58 1 Plug 2 Connecting cable 3 Switch 4 Converter 5 Coupling 6 Protective tube shielded in accordance with EMC Directive 7 Interior concrete vibrator 8 LED protective conducto...

Страница 10: ...Weight Operating weight CECE in kg 14 16 17 Effective diameter approx mm 400 500 600 Dimensions Vibrator diameter mm 40 50 58 Vibrator length mm 330 370 420 Protective tube length mm 5000 5000 5000 We...

Страница 11: ...IVURplus 11 1 2 3 1 Serial number 2 Year of manufacture 3 Type description...

Страница 12: ...han 15 Operate only with an approved ground fault circuit interrupter Damages resulting from non compliance will void any warranty claims Connecting the interior concrete vibrator to the converter The...

Страница 13: ...into operation by pressing the switch 1 The interior concrete vibrator starts up Shutdown Shut down the interior concrete vibrator by pressing the switch 1 Pull the plug out of the power outlet Donot...

Страница 14: ...ecessary Fault Possible cause Remedy Interior concrete vibrator shuts off during compacting Automatic shutoff Do not operate the interior concrete vibrator unless the entire bottle body is covered by...

Страница 15: ...nently Converter experiencing an error Output voltage and output frequency missing Yellow LED flashes 2 x in rapid succession Short circuit or ground fault downstream from the converter output Check t...

Страница 16: ...16 IVURplus Circuit diagram IVUR Frequency converter...

Страница 17: ...IVURplus 17...

Страница 18: ...18 IVURplus...

Страница 19: ...IVURplus 19...

Страница 20: ...berMT youtube com MyWeberMT Weber Maschinentechnik GmbH Im Boden 5 8 10 57334 Bad Laasphe Germany Telefon 49 2754 398 0 Fax 49 2754 398 101 info webermt de www webermt de 085105061 104 IVUR plus_2020_...

Отзывы: