14 IVURplus
Troubleshooting
Maintenance
Work must be carried out using regulation tools, and the operating and maintenance
manual must be complied with for all work.
Maintenance
interval
Maintenance
point
Maintenance
activity
Daily
Entire machine
– Clean unit
– Check connecting cable
and plug for exterior
damage
Every 200
operating hours
– Check bottle neck and
bottle tube for wear,
replace if necessary
Fault
Possible cause
Remedy
Interior concrete
vibrator shuts off
during compacting
Automatic shutoff
Do not operate the interior
concrete vibrator unless the entire
bottle body is covered by concrete
A creepage current
can be detected
on the conductive
parts of the unit
(leakage current)
Grounding conductor
not present
Check / replace connecting cable
Ground fault circuit
interrupter missing /
defective
Check / replace ground fault circuit
interrupter
Power distribution
on site not grounded
Check power distribution on site,
provide for proper grounding of
power distribution on site