Technical data
IVUR 40
IVUR 50
IVUR 58
Noise and vibration values
Sound pressure level LPA
(at the operating station in accordance
with 2000/14/EC, in dB(A))
72
78
81
Hand / arm vibration (effective weighted
value of the acceleration on the guide
handle, determined in accordance with
2006/42/EC, Part 1, in m/s² )
0.7
2.2
2.7
IVUR 40
IVUR 50
IVUR 58
Weight
Operating weight CECE
(in kg)
14
16
17
Effective diameter
approx. mm
400
500
600
Dimensions
Vibrator diameter
mm
40
50
58
Vibrator length
mm
330
370
420
Protective tube length
mm
5000
5000
5000
Weight
kg
7.5
9.5
10.5
Connection vibrator section
Input voltage
(V)
220
220
220
Rated current
(A)
1.8
2.6
3
Frequency
(Hz)
200
200
200
Rated power
(W)
650
850
1050
Connection converter section
Voltage
(V)
230
230
230
Frequency
(Hz)
50
50
50
Rated current
(A)
4.6
4.6
4.6
Rated power
(kVA)
1.6
1.6
1.6
Connecting cable
(m)
10
10
10
Degree of protection
IP 67
IP 67
IP 67