Prior to starting work the owner of the compactor must be familiar with the work environment. The
work environment includes obstacles in the work and traffic area, the bearing capacity of the ground,
as well as the necessary safeguarding of the construction site in the area adjacent to public traffic;
and it includes compliance with traffic regulations.
The soil compactor should only be operated when the protective fixtures are mounted.
The protective fixtures must all be in functional condition.
At least once per shift the compactor must be checked for apparent defects. If there are apparent
defects then operation of the compactor must be stopped immediately, and the responsible person
must be informed. Prior to restarting, compactor malfunctions that have occurred must be corrected.
Always maintain adequate clearance to the edges of pits and embankments.
Do not drive at ninety degrees relative to the slopes to prevent the compactor from tipping over.
After work has been concluded secure the compactor in accordance with statutory regulations,
particularly in the area of public traffic surfaces.
Operation under difficult conditions
Never inhale the exhaust gas. It contains carbon monoxide, a colorless and odorless gas that
is extremely hazardous, which, if inhaled even briefly, can cause unconsciousness and death.
Therefore, never operate the engines in enclosed areas or in areas that are poorly ventilated
(tunnels, caves, covered pits, etc.).
Be particularly cautious when operating the engine in the vicinity of people and livestock.
The soil compactor described in this operating manual is suitable for use in trenches that are
deeper than shoulder height, provided the following basic conditions have been met:
– trench width at least 1.5 m
– trench depth no more than 3.0 m
– open trench width at least 10 m
– slight wind movement in the trench
– the compactor is used for periods of no more than 4 x 15 minutes per shift, interrupted by breaks
(each approx. 1 hour)
If these basic conditions are not satisfied, the owner is required to implement the protective measures
identified as necessary to avoid CO poisoning during his own risk assessment. These may include:
– use of zero-emission compacting equipment
– blower-supported ventilation with a fan forcing air along the length of trench
The use of respiratory equipment during operation of this gasoline-powered compactor without docu-
mented evidence of conformity and without the necessary precautions
is generally not permitted!
– as CO will accumulate in the blood after repeated use
– as CO filters have a short service life