23
WARNING
If lubricating oils and fuel come into contact with skin, they can
cause skin cancer.
Wear protective gloves.
If skin contact has occurred, wash the affected areas
thoroughly.
8.2. Description of the maintenance operations
Vibrator oil: SAE 10W40 (-10~ + 50 °C),
API-CD CE-CF-CG or SHPD or CCMC-D4-D5-PD1.
Fill quantity: 0.05 l.
8.2.1. Change the oil in the
exciter
Start the engine and allow the engine to warm up for a few
minutes.
Switch off the engine.
Park the machine on a level subsurface.
Loosen the oil drain plug (1).
Use a suitable pump to suck out the oil.
Fill fresh oil into the exciter in accordance with the specifica
-
tion.
Close the oil drain plug.
1
Shut down the machine.
Remove the V-belt guard (1).
Check the V-belt (2) for cracks and wear.
Replace the V-belt if it shows signs of extensive wear or
other damage.
Fit the V-belt guard.
8.2.2. Check V-belt
2
1