DVS Fast Charging System  

Operation and Maintenance Manual 

 

09910-W-03-02 

Page 

26 of 27

 

 Webasto Charging Systems, Inc. 

FF

 

This fault indicates a Charger Configuration error.  Use the Charger Configuration menu 
to clear the ‘Battery Backed RAM’.  Reconfigure the Charger and cycle power to the 
system.  If the fault persists, contact your Authorized DVS/MVS 330 Fast Charging 
System Service Provider. 

GG

 

Not used 

HH

 

Not used 

II

 

If the display is intermittent or dark, the display connector may be loose.  Open the unit 
and inspect the control board to display interface.  Check to make sure that all standoffs 
on the control board are screwed down firmly to the front panel and are securely holding 
the control board at all locations.  Correct any problems found with the standoffs and 
cycle power to the unit.  If this does not correct the problem, replace the door assembly.  
Burned out LED’s usually indicate a damaged membrane.  Replace the door assembly. 

JJ

 

A power imbalance fault can result from a contactor problem, a loose connection in the 
high current path of one channel, a malfunction in the current sensor, or a malfunction on 
the control board.  Check all connections to the contactors, current sensors and output 
connections.   If the problem persists, contact your Authorized DVS/MVS 330 Fast 
Charging System Service Provider. 

KK

 

If a VBAT MISMATCH error occurs, check the display and observe the voltage.  If the 
voltage looks correct for the battery, the problem is most likely in the high current path or 
the voltage sense path.  Check for continuity throughout the high current path from the 
power board to the battery in the vehicle.  Check that all cables connections are tight and 
that all contactors in the path are functioning properly.  If the problem persists, contact 
your Authorized DVS/MVS 330 Fast Charging System Service Provider. 

LL

 

If the voltage observed on the unit display does not seem appropriate for the battery in 
use, the problem is in the BMID.  Verify the BMID Configuration is correct for the 
battery.  If the problem persists the BMID should be replaced.  Contact your Authorized 
DVS/MVS 330 Fast Charging System Service Provider. 

MM

 

If an invalid pilot signal is indicated, check the pilot signal wiring.  If the pilot signal 
wiring and connections check out, check the charger with another vehicle to isolate the 
problem to either the charger or the vehicle.  If the problem goes away when another 
vehicle is used, replace the BMID in the vehicle that caused the fault.  If the fault persists 
when the vehicle is changed, replace the control board in the unit. 

NN

 

Reseat the power stage Temp Sense connectors.  Check each heat sink thermistor 
(resistance should be greater than 60K ohms).  If the problem persists, contact your 
Authorized DVS/MVS 330 Fast Charging System Service Provider. 

OO

 

Check the Charger output wiring and connectors. Ensure that all the power and signal 
connectors are completely mated, and that there is no physical damage to the connector 
or pitting on the contacts that could cause poor connections.  If a connector or the 
associated wiring is damaged, replace immediately. 

 

 

Содержание PosiCharge DVS 330

Страница 1: ...Operations and Maintenance Manual GSE Intelligent Fast Charging System DVS 330 380VAC 50Hz with Emergency OFF ...

Страница 2: ...e production models may vary No portion of these materials may be duplicated used or disclosed without prior written permission from Webasto Charging Systems Inc Disclaimer this manual includes the latest information available at the time of printing Webasto Charging Systems Inc Reserves the right to make changes to this manual and or product without further notice Changes or modifications to this...

Страница 3: ... AND ACCESSORIES 9 4 SYSTEM INSTALLATION 9 5 OPERATION 10 5 1 SYSTEM START UP 10 5 2 CHARGING 11 5 3 EQUALIZATION 13 5 4 FULL OVER CHARGING 14 5 5 REDUCED CHARGING 14 5 6 VIEWING CHARGE DATA OR FAULT WARNING SCREENS 14 5 7 DATA LOGS CHARGER CONFIGURATION AND ADVANCED PROGRAMMING FEATURES 15 6 DVS MVS 330 PERIODIC MAINTENANCE 17 6 1 DC POWER OUTPUT CABLE INSPECTION AND SERVICE 17 6 2 INTAKE AND EXH...

Страница 4: ...FIGURE 5 4 FRONT PANEL LAYOUT 12 FIGURE 5 5 CHARGE COMPLETE SCREENS 13 FIGURE 5 6 REPRESENTATIVE CHARGING DATA SCREENS 14 FIGURE 5 7 REPRESENTATIVE FAULT OR WARNING SCREENS 15 FIGURE 5 8 TOP LEVEL MENU FOR ADVANCED FEATURES 16 List of Tables TABLE 5 1 LED LABELS AND DEFINITIONS 13 TABLE 6 1 PERIODIC MAINTENANCE SCHEDULE 17 TABLE 7 1 PROBLEM SYMPTOMS AND ACTION KEY 19 TABLE 7 2 FAULT CODES AND ACTI...

Страница 5: ...s automatically performed on the pack according to a pre set schedule This results in better use of the batteries with minimal effort on the user s part 1 1 Getting Started First familiarize yourself with the caution symbols in Section 2 To get the system up and running quickly perform the following steps 1 Ensure the DVS MVS 330 Fast Charging System installation and utility power requirements are...

Страница 6: ...ck hazard or possible damage to the equipment during installation and service NOTE Offers helpful information for installation or usage but does not contain personnel or equipment safety related information 2 2 Safety Instruction CAUTION BEFORE YOU BEGIN Read all instructions and cautionary markings on the Industrial PosiCharge DVS MVS 330 System Assembly Make sure you also read the IMPORTANT SAFE...

Страница 7: ...TB1 on the interior top wall of the PowerStation even after the OFF and or EPO button has been pressed Disconnect battery charger from input power and battery connections before installing or servicing Lockout tagout input power according to OSHA 29 CFR 1910 147 Do not use when in standing water The charging leads must be capable of the full rated current of the DVS MVS 330 system and inspected fr...

Страница 8: ...o not install or place unit on over or near combustible surfaces Do not install unit near flammables Do not block or filter airflow to the unit allow minimum of 6 clearance around unit Ensure that the BMID is properly installed according to the BMID installation instructions Replace blown fuses only with same type and rating of fuse Do not overload building wiring be sure the power supply system i...

Страница 9: ...progress at 80 complete fully charged or in equalization A fault warning LED serves to alert the user to fault conditions The DVS MVS 330 system operates with a small monitoring device mounted on the battery called the battery monitor identifier BMID The BMID enables the charger to automatically adjust the charge to match the requirements of any battery type 3 1 Options and Accessories The followi...

Страница 10: ...g the large red Emergency OFF button will also remove all output power Internally the accessory 120VAC still remains enabled when the system is powered off using the OFF or Emergency OFF button Turn off the AC input to the system and remove all output connections prior to performing any service to the system Before restarting the system after any emergency be sure the system has been returned to a...

Страница 11: ... of voltage current and temperature will vary with the type of battery pack being charged Step 1 Starting a Charge To start charging connect the battery to either charge port of the charger The charger will establish communication with the BMID calculate the current State Of Charge SOC identify the correct charging profile and start charging The charger will display the corresponding Status screen...

Страница 12: ... left facing arrow at the left of line 1 This indicates that the display applies to charge port A A right facing arrow at the right of line 1 indicates that the display applies to charge port B Figure 5 4 Front Panel Layout Charger Ready Connect Vehicle Vehicle Connected Getting Config Info Starting Fast Charge Please Wait 30 Sec Charging 53 50 1 V 500A Vehicle Connected Comm Established Count Dow...

Страница 13: ...he screen will indicate the method by which the charge was stopped The display will also contain the data values obtained at the end of charging see Figure 5 5 Figure 5 5 Charge Complete Screens NOTE If the operator disconnects the cables without pressing STOP the charger will immediately stop charging and prevent any arcing or damage to either the charger or battery Step 3 Disconnect battery cabl...

Страница 14: ...s enabled Full Over Charging will be performed automatically The time window as well as the length of Over Charging is set through the Full Over Charge Setup submenu of the Charger Configuration menu 5 5 Reduced Charging Reduced Charging allows the user to reduce power consumption during peak rate periods The feature limits the output current to a predetermine rate during a user defined time windo...

Страница 15: ...lt or Warning Screens 5 7 Data Logs Charger Configuration and Advanced Programming Features The DVS MVS 330 Fast Charging System s user interface allows a trained user to configure many of the charge parameters and review recorded data stored in the system s internal data logger All configuration programming is performed through the UI menus that are accessible directly through the display and the...

Страница 16: ...he stored charge history and equalization data 5 BMID Configuration A programming mode for modifying the BMID parameters of the unit s presently connected Requires an access code to enter this mode 6 Display Application Version Information Allows user to view software version and hardware configuration information ANY STATUS OR CHARGING SCREEN Charge Event Log Fault Warning Log Charger Configurati...

Страница 17: ...Connector contacts must also be inspected for corrosion or pitting Immediately replace cables and or connectors that exhibit any damage Refer to the DVS MVS 330 System Installation Manual for output cable installation instructions WARNING Use only connectors and cable that are rated for the full continuous current rating of the unit If you have questions regarding a specific cable assembly or need...

Страница 18: ...hat may be displayed on the front panel of the DVS 330 or PowerStation are listed in Table 7 2 Find the fault code displayed in the first column and review the fault description in the second column Use the table s third column to identify the appropriate action for that fault See section 7 2 below for a detailed description of each action Charge Termination Codes are listed in Table 7 3 This tabl...

Страница 19: ... signal pins Battery over discharged BMID is bad or reading out of range Failed Control Board OO F F OO EE K G A Charger stops charge before complete Battery overheated Loss of communication with BMID Bad cell within pack Charger overheating Incorrect Charger configuration H P F OO I AA J Charger works intermittently Loose input or output wiring Loose BMID connections Low local utility voltage Cor...

Страница 20: ...h Incorrect equalization schedule Incorrect BMID configuration Battery temperature too high O J H P Battery temperature too high Loose battery interconnects Incorrectly installed temp sensor Incorrect BMID configuration Batteries under watered Cell SOC mismatch Q F G J P I Charge connector arcs when disconnected Failed Control Board A Noisy unit Loose Sheet metal Loose Fan blade or mount Noisy Tra...

Страница 21: ...istor failure V 110 PS1 General Failure Powerstage 1 port A voltage mismatch fault W 111 Not used 112 PS2 Overvoltage Powerstage 2 port B voltage too high S 113 PS2 Overcurrent Powerstage 2 port B current too high T 114 PS2 Undercurrent Powerstage 2 port B current too low S 115 PS2 Trans Failure Powerstage 2 port B transistor failure V 116 PS2 General Failure Powerstage 2 port B voltage mismatch f...

Страница 22: ...l voltages don t match KK 144 Battery Overdischarged on Port A Battery excessively discharged K 145 Not used 164 Invalid Pilot on Port B Battery connected with invalid pilot circuit MM 165 Chrg Vdc Port B Low Battery voltage too low for charger Z 166 Chrg Vdc Port B High Battery voltage too high for charger Z 167 BMID B Vbat Too Low Battery voltage too low for BMID L 168 BMID B Vbat Too High Batte...

Страница 23: ... installed properly Refer to BMID manual G Visually inspect the BMID and the thermistor If the potting of the BMID looks cracked or the thermistor appears corroded avoid erratic charging by replacing these components even if functional problems have not yet occurred Temporarily attach another BMID or thermistor to the pack If the problem is resolved replace the bad component If the problem persist...

Страница 24: ...he battery charge path for shorts or opens Check the battery for defective or damaged cells If no problems are found replace the BMID M This fault is usually the result of an unprogrammed BMID or an improperly programmed BMID Using the BMID Configuration menu verify that the BMID installed on the pack has the correct battery manufacturer type code the correct capacity of the cells and the correct ...

Страница 25: ...ider X Indicates that the 150V DC Buss dropped below 110V or rose above 170V There may be a miss wire in the utility wiring to the Charger Contact your Authorized DVS MVS 330 Fast Charging System Service Provider Y If there is no sign of excessive heat a temperature fault may indicate a faulty temperature switch Contact your Authorized DVS MVS 330 Fast Charging System Service Provider Z Check to m...

Страница 26: ...oblem is most likely in the high current path or the voltage sense path Check for continuity throughout the high current path from the power board to the battery in the vehicle Check that all cables connections are tight and that all contactors in the path are functioning properly If the problem persists contact your Authorized DVS MVS 330 Fast Charging System Service Provider LL If the voltage ob...

Страница 27: ... FINISH AHR LIMIT Finish Charge Amp hours exceeded 12 FINISH BAT TEMP LIMIT Finish Charge battery temp limit 13 FINISH BMID COM LOST Finish Charge BMID communications lost 14 FINISH TIME LIMIT Finish Charge CV mode time limit exceeded 15 FINISH USER STOP Finish Charge user stopped stop button or disconnected 16 FULL AHR LIMIT Full Over charge Amp hours exceeded 17 FULL BAT TEMP LIMIT Full Over cha...

Отзывы: