ON
Push 1x, display will show ON. During first start-up display will also flash the current
frequency (50H=50Hz)
after INIT; finally the room temperature will appear. Air-blower (CPAC) or
evaporator water-pump (Chiller) will start.
Depending on controller setting unit will start in cooling or heating mode. When unit
won't start, error codes
will appear. See Troubleshooting.
OFF
Push 1x, unit and display will automatically shut-off when running.
MEMO
Push 1x, to memorize new settings during programming.
RETURN
Push 1x, display will return to room temperature during FUNCTION mode
programming.
FUNCTION Push 1x, shows b... for blower setting.
Push 2x, shows E** or H** for evaporator temp.
Push 3x, shows CODE, entering code will give access to programming mode level
2. (Default=64)
Change b... or enter CODE by pushing up or down key, after 5 seconds new
settings will be auto memorized.
UP
Push 1x will show actual set point, further pushing will raise the set point and
memorize automatically.
BLOWER
SPEED
Shows actual blower setting, bA automatic or b1-b5 for manual, adjustable by up or
down key.
DOWN
Push 1x will show actual set point, further pushing will lower the set point and auto
memorized.