Page 24 5-1-GL-GL-SUL-00028 SLS Baseline 8900 Setup and Calibration
Manual
WELLWIZARD SETUP
Refer to WellWizard Server Manual 5-1-GL-GL-SUL-00004 for Well and user setup. Once the well and
user has been set up, follow these steps to set up communication with the Baseline 8900:
1)
Input “qw” to get the UWID of the well that the Baseline 8900 must be set up on
2)
Input “cd /ww/well/well/UWID/config to get into the directory for that well
3)
Input “nano programs” to edit the programs file
4)
Delete the hash tag before the 8900BL line and change the “serX” to the correct serial
5)
Type “WWreboot” to reboot WellWizard so that the changes will take place