6 Lifting supports   
7 Warranty, specification & conformity

6 Lifting Supports 

We recommend ALTOSLINGS to be used with HERON hoists. A mesh sling will dry more quickly.
For their use please refer to the specific instructions regarding the devices.

7 Warranty, Specification & Conformity

Our hoists are warranted for 12 months from the date recorded in the shipping document. During this period parts that may be 
found to be defective will be replaced or repaired free of charge by WEALDEN REHAB. The warranty does not cover:  
effects of normal wear and tear, damage caused during transport and/or due to improper use of the equipment.
Repair is carried out by our authorised dealers and/or at our premises; therefore, the transport costs for delivering any returns shall 
be paid by customer.
For warranty service, and in any case if you need technical assistance or want to lodge a complaint, please contact our Technical 
Assistance Manager.

Technical sheet

N3242-1/
N3242-3

N3242-0/
N3242-2

N2463

N2465

10.4.14255

N5429

Item name

Electric Liftpool

Electric Liftpool-
seat (without 
mobile base)

Socket

Plate

Legrest

Mobile base
(without seat)

Dimensions (cm)

See figures

Weight

35-38max.

55-58max.

5

22

5

10

Max. capacity

135

135

-

-

-

-

Use

Equipment for temporary use: 
10%/max 6min/hour

Electric power
supply

Internal control box 24V-2.9Ah
Battery charger:230V±10%/50Hz/
14VA:

Fuses

Internal components are not  
accessible

Declaration of conformity

Product name 

Item code 

Type of product 

HERON  E -  HERON MAX  E 

Heron  plate - Heron  socket 

Legrest for Liftpoolseat 

Mobile base for  Heron seat

10.4.14190 - 10.4.14230-10.4.14240-10.4.14250 10.1.14185 - 

10.1.14165 

10.4.14255 

10.4.14256 

Swimming pool hoist 

accessories 

Class it belongs to 

(Art. 8  of Italian Law Decree No. 46 of 

24/03/1997) 

Class        (Liftpool and Liftpoolseat only) 

(Art 2.2.4-5 of CEI Standard 62.5)  

Equipment powered internally 

Type        (Liftpool and Liftpoolseat only) 

(Art 2.2.24-25-26 of CEI Standard 62.5) 

The items described above are made in conformity with European Directive  93/42

 

CHINESPORT S.p.A. 

 (Legal Rep.) 

Содержание N3242-1 Heron Lift E

Страница 1: ...ehab com Heron Pool Lift Operation Maintenance Manual N3242 1 Heron Lift E with spreader bar N3242 3 Heron Lift Max E with spreader bar N3242 0 Heron Lift E with integral seat N3242 2 Heron Lift Max E with integral seat N5429 Mobile Base For Liftpoolseat N2463 Pool Socket N2465 Pool Plate ...

Страница 2: ...ental conditions 3 Safety Page 4 General warning Proper and improper use Emergency lowering and stop functions Setting up for use Installing the anchor systems Main components and dimensions cm Use 4 Battery Charging Page 4 5 Maintenance Cleaning Page 9 Troubleshooting Technical assistance and spareparts 6 Lifting Supports Page 10 Lifting supports 7 Warranty Specification Conformity Page 10 Warran...

Страница 3: ... failure to comply with these instructions Target readership This manual is intended for users therapist attendant it must always be kept with the equipment and stored in a safe place for future reference 2 Equipment Description Intended use operation Electric hoist for easy transfer of disabled users into a swimming pool Painted stainless steel Available versions HERON with a sling bar and HERON ...

Страница 4: ... if no lifeguard is at the pool Emergency lowering stop functions The machine can be stopped by depressing the lift lower buttons pressing the emergency button Fig 3 to disable the button and put the equipment back into operation rotate the button in the arrow direction Warning Press the emergency button when you need to stop the equipment immediately The emergency lowering can be enabled by press...

Страница 5: ...tem must be capable of withstanding the load applied Pool Socket Determine the proper position for installing the hoist see fig 2 Bore a hole 90mm in diameter and 240mm deep Put a shim on the bottom of the hole so that the socket and cap are level with the floor Remove the socket and fill 1 4 of the hole with fluid quick cement Insert the socket and press it until the cap is flush with the floor M...

Страница 6: ...he first time 7 Connect the remote control and the actuator connectors to the control box Fig 3 Make sure that the pins are fully inserted otherwise the hoist may not work Use Heron with spreader bar 1 Apply the sling to the patient refer to special instructions 2 Press the Lower button on the remote control until the desired height is achieved and connect to the sling 3 Raise the patient by press...

Страница 7: ...ase item N5429 for Heron Seat The mobile base is an accessory to be applied to the seat of the HERON to transfer the patient from the changing room to the hoist and vice versa The mobile base is supplied with the seat To attach the seat to the hoist do as follows Fig 4 1 Transfer the patient onto the seat mobile base with the wheel brakes engaged fold back the safety armrests 2 Unfold the footrest...

Страница 8: ...d battery upwards 2 Connect the power supply unit to the mains with a voltage of 220V 50Hz and insert the charging pin into the relevant socket located on the battery 3 When charging is completed disconnect the battery charger and reinsert the battery into its seat control box until it clicks into place Battery life can be extended if you avoid discharging batteries completely We recommend you to ...

Страница 9: ...water spray Troubleshooting Problem Cause Solution The equipment won t work Emergency button is ON Disable Connectors disconnected or improperly plugged in Check connections Flat batteries Recharge Burnt battery protection fuse Contact service centre Damaged control box Contact service centre Batteries do not recharge Battery charger is not powered or is improperly connected Check connections Chec...

Страница 10: ...odge a complaint please contact our Technical Assistance Manager Technical sheet N3242 1 N3242 3 N3242 0 N3242 2 N2463 N2465 10 4 14255 N5429 Item name Electric Liftpool Electric Liftpool seat without mobile base Socket Plate Legrest Mobile base without seat Dimensions cm See figures Weight 35 38max 55 58max 5 22 5 10 Max capacity 135 135 Use Equipment for temporary use 10 max 6min hour Electric p...

Страница 11: ...ldenrehab 01634 813388 hello wealdenrehab com 8 Inspection record sheet Equipment Manufacturer CHINESPORT S p A 33100 Udine Italy Serial number Date of first installation Date of inspection Operations carried out Technician s name Signature Next due date ...

Отзывы: