WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-III
1. Power-up the modules and make their UARTs accessible by the host(s) (115200 Baud,
8n1). After the power-up or after reset the following sequence is sent from the module to
the host.
Info
Module A
Module B
⇐
Response
: Module A
started in
ACTION_IDLE
mode.
02 41 02 00 01 01 41
⇐
Response
: Module B
started in
ACTION_IDLE
mode.
02 41 02 00 01 01 41
2. Request the
of both modules.
Info
Module A
Module B
⇒
Request
with settings index 4
02 10 01 00 04 17
⇐
Response
of
module A is
0x55 0x00 0x00 0xDA 0x18 0x00
02 50 07 00 00
55 00
00 DA 18 00
C2
⇒
Request
with settings index 4
02 10 01 00 04 17
⇐
Response
of
module B is
0x11 0x00 0x00 0xDA 0x18 0x00
02 50 07 00 00
11 00
00 DA 18 00
86
3. Configure the parameter
to use "Long range connection mode".
Info
Module A
Module B
⇒
Perform
with settings index 28
and value 0x02 (Long range connection mode)
on module A
02 11 03 00 1C 02
00 0E
⇐
Response
(Module will restart
to adopt the new value)
02 51 01 00 00 52
⇐
Response
02 41 02 00 01 01 41
⇒
Perform
with settings index 28
and value 0x02 (Long range connection mode)
on module B
02 11 03 00 1C 02
00 0E
⇐
Response
(Module will restart
to adopt the new value)
02 51 01 00 00 52
⇐
Response
02 41 02 00 01 01 41
4. Connect module A to module B via Bluetooth
®
.
Info
Module A
Module B
⇒
Request
with
of
module B
02 06 06 00
11 00 00
DA 18 00
D1
⇐
Response
: Request
understood, try to connect now
02 46 01 00 00 45
Order code 2611011024000
59
Version 1.8 , July 2022