background image

Installation Procedure

1)  Switch off the mains electrical supply.

3)  Check that rating shown on luminaire label 

conforms with mains electrical supply.

 (example)

 

05/19 IP66

VLS420-LED

 

220-240V / 50-60 Hz

131-XXXX 

 

SOE XXXXXXX

LED 3000K 18W 

item no. XXX

2)  Remove wall flange

 A

 from cover 

B

 by releasing 

screws 

C

.

Fixture is intended to be mounted over a UL listed 
junction box (not supplied by WE-EF), use provided
wall plate to cover boxes larger than the outer 
dimensions of the luminaire.

4)  Determine positions for four fixing screws 

D

Drill relevant holes 

E

 and insert wall plugs 

F

.

  

ATTENTION:

 Ensure not to damage any electrical

cable, water pipe or other items drilling holes.

5)  Feed the mains supply cable 

G

 (and the second 

cable 

H

 for through wiring, if required) through 

the cable gland 

I

 at the side of the wall flange, 

while setting and fixing wall flange in position. 
The cable gland 

I

 is suitable for cable diame-

ters 0.276 to 0.472 in.

6)  Ensure the point arrow mark 

R

 on the wall 

flange aims upwards and that the luminaire is 
properly oriented. 
Fix the wall flange by inserting and tightening 
screws 

D

.

7)  Connect mains supply leads to respective

terminals in terminal connectors 

as follows:

  Non dimmable luminaires

Phase to L1, Neutral to N and Earthing to

 0-10V

Phase to L, Neutral to N, 0-10V+ to D+,

  0-10V- to D- and Earthing to 

Luminaire Replacement

The LED module can be replaced by qualified per-
sonnel with appropriate professional qualifications 
and with standard tools.  To do this, disconnect 
the luminaire from the power supply and open it. 
Replace the LED module and close it again. Make 
sure that the seal is correctly positioned and close 
the luminaire carefully.

8)  Tighten cable gland(s) 

I

.

9)  Reposition cover 

B

 on wall flange 

and secure 

in position by evenly tightening the screws 

C

5 Nm (44.3in-lb).

Содержание SLS400 Series

Страница 1: ...ied the persons responsible for the modification shall be considered as manufacturer SLS400 VLS400 LED_130122 006 1059 Technical specifications are subject to change WE EF 2022 we ef com WE EF LIGHTING USA Tel 1 724 742 0030 info usa we ef com WE EF LIGHTING Installation and Maintenance Instructions for Wall luminaires surface mounted SLS400 LED Series VLS400 LED Series ...

Страница 2: ...tice If the luminaire is modified by anybody other than the original manufacturer then the warranty will no longer be valid and shall become the full responsibility of the modifying person organisation Claims based on defects attributable to improper installation and or application and the consequences thereof are excluded In case of component failure LED replacement due to abnormal circumstances ...

Страница 3: ... wall flange while setting and fixing wall flange in position The cable gland I is suitable for cable diame ters 0 276 to 0 472 in 6 Ensure the point arrow mark R on the wall flange aims upwards and that the luminaire is properly oriented Fix the wall flange by inserting and tightening screws D 7 Connect mains supply leads to respective terminals in terminal connectors J as follows Non dimmable lu...

Страница 4: ... E H G D I J R G D I J Individual connection Through wiring Torque Screw Torque M4 max 2 0 Nm 17 7 in lb M5 max 4 0 Nm 35 4 in lb M6 max 6 0 Nm 53 1 in lb M8 max 15 0 Nm 132 8 in lb M16 max 100 0 Nm 885 1 in lb ...

Отзывы: