5
ON-OFF / ADVANCED
1-10 V
DALI
DMX
BASIC
Wiring Diagram
WE-EF
Advanced
, CC Wireless DMX
and non dimmable
luminaires
Class I
Phase to
L1
, Neutral to
N
and Earthing to
Class II
Phase to
L1
, Neutral to
N
WE-EF Basic
Class I
Phase to
L1
, Control Phase to
L2
,
Neutral to
N
and Earthing to
Class II
Phase to
L1
, Control Phase to
L2
, Neutral to
N
1-10V / DALI (INC TW) / CC (DMX)
Class I
Phase to
L1
, Neutral to
N
and Earthing to ,
1-
10V, DMX to
+
and 1-10V, DMX to
–
DALI to
D
Class II
Phase to
L1
, Neutral to
N
,
1-10V, DMX to
+
and 1-10V, DMX to
–
for DMX shield on
'S'
DALI to
D
Notice:
All FLC200 luminaires are vented, and have a venting element. For the FLC230/240/260 the housing contains a M12
venting element (IP68). In the FLC220 the venting element is contained in the main entry gland. Under no circumstances
are the glands to be removed from this luminaire. The secondary gland is supplied with a blanking element if not required
for cabling, the blanking element retains the rated IP of the luminaire.
For operation as color changer the floodlights of the FLC200-CC series require a DMX control signal. The operation without
control signal may lead to error.
The operation of the Wireless DMX version requires the luminaire to be configured to a suitable wireless access point. The
luminaire is supplied addressed but unpaired to an access point. All FLC200-CC have RDM compatible drivers