Installation 

The product must be installed and maintained by a suitably

 

qualified professional in compliance with latest building/

construction and/or electrical regulations and relevant 

legislation.

Warning:

 

Switch off 

and isolate 

mains electrical supply 

prior to

 

installing and connecting the luminaire. Do not 

open 

the 

luminaire while mains supply is switched on.

Notice:

 

If the luminaire is modified by anybody other than

 

the original manufacturer, then the warranty will no longer

 

be valid and shall become the full responsibility of the 

modifying person/organisation. Claims based on defects 

attributable to improper installation and/or application, and

 

the consequences thereof, are excluded. 

In case of component failure due to abnormal 

circumstances or at end of life, replacement must be carried 

out

 

by a suitably qualified and trained professional.

In case of questions please contact our technical hotline: 

+

61

 

458 933 399

 (from Monday - Friday from 0

7

.00 until

 

1

9

.00 hours.

Installation Procedure

1)

Prior to electrical connection, proceed with mechanical

 

installation by firmly fixing stirrup 

A

 

to optional mount-

ing accessory or directly to a suitable surface.

Aim luminaire.

Caution:

 

Make sure not to damage any electric cable,

 

water pipe or other devices while drilling holes.

2)

Switch off 

and isolate 

the mains electrical supply. 

3)

Remove gear box cover 

B

 

by releasing screws 

C

.

4)

Check that rating shown on the luminaire label con-

forms with the mains electrical supply. 

5)

Feed mains supply cable 

D

 

through cable gland 

E

.

 

An 

additional 

M20 

gland is supplied to allow loop 

through of supply cabling or alternative DMX cabling 
arrangements.

6)

Connect to the correspondingly marked contacts of

 

terminal 

F

, according to the wiring diagram.

 

Tighten 

cable gland 

E

 

firmly.

7)

Reposition gear box cover 

B

 

and tighten screws 

C

evenly.

8)

Loosen the two screws 

G

 

slightly. Aim luminaire (see

 

illustration), tighten screws 

G

 

firmly (

100Nm

). 

In addition, tighten screw 

H

 

(max. 

6Nm

) to secure

 

orientation of luminaire.

Содержание FLC230-CC

Страница 1: ...EF LIGHTING Installation and Maintenance Instructions for Projectors FLC200 LED Series FLC200 CC LED Series FLC200 TW LED Series FLC200 CC Wireless DMX Series INSTALLER HOTLINE 61 458 933 399 7am 7pm AEST ...

Страница 2: ...1 IEC61643 1 1 Luminaires designated with the type code A will have an internal Surge Protection Device SPD fitted Street and area luminaries are supplied with an external SPD D Where an external SPD is supplied it must be fitted as per the supplied instructions to maintain warranty conditions Ensure that all required surge protection measures are in place and activated prior to luminaire installa...

Страница 3: ...W 52W FLC240 24 LED 48W 72W 104W FLC260 36 LED 72W 108 W 155W FLC220 TW 6 LED 22W FLC230 TW 12 LED 44W FLC240 TW 24 LED 88W FLC260 TW 36 LED 136W Protection IP66 IK07 Class I ta 25 C Windage area FLC220 0 030 m FLC230 0 054 m FLC240 0 090 m FLC260 0 116 m Weight FLC220 max 4 5 kg FLC230 max 8 0 kg FLC240 max 13 8 kg FLC260 max 18 8 kg Tools required Screwdriver TX25 TX30 TX70 Screwdriver with blad...

Страница 4: ...technical hotline 61 458 933 399 from Monday Friday from 07 00 until 19 00 hours Installation Procedure 1 Prior to electrical connection proceed with mechanical installation by firmly fixing stirrup A to optional mount ing accessory or directly to a suitable surface Aim luminaire Caution Make sure not to damage any electric cable water pipe or other devices while drilling holes 2 Switch off and is...

Страница 5: ...30 max 15 0 Nm TX70 max 100 0 Nm Notice The wireless DMX version has the Wifi receiver attached to the back case C If required the cover can be completely removed by disconnecting the white in line connector plug When replacing the back cover ensure all wires are clear of the back case sealing rib ...

Страница 6: ... vented and have a venting element For the FLC230 240 260 the housing contains a M12 venting element IP68 In the FLC220 the venting element is contained in the main entry gland Under no circumstances are the glands to be removed from this luminaire The secondary gland is supplied with a blanking element if not required for cabling the blanking element retains the rated IP of the luminaire For oper...

Страница 7: ...6 ...

Страница 8: ...3 4 74 99 14 40 info france we ef com WE EF HELVETICA Switzerland Tel 41 22 752 49 94 Fax 41 22 752 49 74 info switzerland we ef com WE EF LIGHTING United Kingdom Tel 44 844 880 5346 Fax 44 844 880 5347 info uk we ef com www we ef com Liability WE EF LIGHTING accepts no liability when damage is caused by improper use or installation If any luminaire and or accessory is subsequently modified the per...

Отзывы: