3) Loosen the screws
C
and remove the cover
B
.
4) Check that rating shown on the luminaire label
conforms with the mains electrical supply.
C
A
G
B
2) Switch off the mains electrical supply.
12/17 IP66
FLC210 LED
120-277V / 60 Hz
139-XXXX
SOE XXXXXXX
LED 3000K XXW
item no. XXX
G
D
C
B
5) Feed mains supply cable
D
through cable
gland
E
.
88
0-10V
ON-OFF
L
N
L
N
D
D
E
F
6) Connect to the correspondingly marked contacts
of terminal
F
, according to the wiring diagram.
Tighten cable gland
E
firmly. For connection
and wiring diagram of CC-luminaires see sepa-
rate connection diagram.