5
7) Ensure that all surface are clean and dry. Position
OXPLQDLUHRYHUPRXQWLQJƃDQJH
A
and reconnect
terminal connector
C
. Turn luminaire towards
object to be illuminated. Tighten screw
B
.
5) Feed mains supply cable
G
through the pres-
sure screw
I
ZKLOHVHWWLQJPRXQWLQJƃDQJH
A
LQSRVLWLRQ7RƂ[PRXQWLQJƃDQJH
A
, insert and
tighten screws
D
. Ensure nylon washers stay
in position. The pre-installed packing ring
H
is
suitable for cable diameters 7 to 9.5 mm. For
larger cable diameters (9 to 12 mm) use the
auxiliary packing ring supplied.
6) Connect mains supply cable
G
leads to
respective terminals in terminal connector
C
:
a) ON/OFF (L = Phase, N = Neutral,
= Earthing)
b) 1-10 V/DALI (L = Phase, N = Neutral,
= Earthing, DA/DA = DALI control line,
D–/D+ = 1-10 V control line).
Tighten pressure screw
I
.
8) Loosen screws
M
slightly. Aim luminaire in
desired direction, retighten screws
M
.