F
G
D
E
C
L, N, PE, D+, D-
Linear inground luminaire ETV100 pic. 1
F
E
C
L, N, PE
DMX
D
G
Linear inground luminaire ETV100-CC pic. 1
Installation luminaire uplight ETV
1) Switch off mains electrical supply.
2) The luminaire is pre-wired and the lamp/LED inclu-
ded. An opening of the luminaire is not necessary.
3) Take the installation cover A and the spacers
E
out
of the blockout
B
.
4) Connect the connecting cable with the provided
UL410–D gel–filled wire nuts of the luminaire and
place the clamp inside the connection sleeve
D
.
5) Place the connection sleeve
D
and the luminaire
C
inside the blockout. Make sure no cable is squeezed.
6) Install the spacer
E
. In case the space for the lumin-
aire(s) is not sufficient you can remove individual
silicone buffer
G
.
To remove the luminaire unfasten the screws
F
from
the spacer
E
until you can clasp these and pull out the
spacer in an upwards direction.