Dosing Device Foamdos V6
Index: 01
Date modified: 26/08/2019
OI No.: BA DW 025-00 Foamdos V6 EN.DOCX
Page 22 of 37
6.5.4
Test foam
Foam generation for function control.
Value in seconds.
Function:
The peristaltic pump is running.
The “Foam” solenoid valve opens.
The control LED on the solenoid valve lights up.
The compressor is running.
6.5.5
Test compressor
Only for function control.
Switch on compressor.
Function:
The compressor is running.
6.5.6
Test SV flush
Only for function control.
Start flushing with water.
Function:
The “Flush” solenoid valve opens.
The control LED on the solenoid valve lights up.
6.5.7
Test SV foam
Only for function control.
Open the “Foam” solenoid valve.
Function:
The “Foam” solenoid valve opens.
The control LED on the solenoid valve lights up.
6.5.8
Test emptying (accessory drain valve)
Only possible if the “Emptying” solenoid valve is connected.
Only for function control.
Emptying the foam line after flushing via the solenoid valve.
Function:
The “Emptying” solenoid valve opens.
The control LED on the solenoid valve lights up.
6.5.9
Test pump
Only for function control.
Start the peristaltic pump.
Function:
The peristaltic pump is running.