Liquid level controls:
Float controls are supported by mounting a bracket which is attached to the
borehole wall, deck, or junction box. Use cable grips to hold the cables in
place during instillation. The level of control can be changed by loosening the
handle and adjusting the cable length according to the plans and
specifications. Make sure the float controls are correctly placed and the
pump is completely submerged when the level control is “Off”.
Electrical connections.
Power and Cables Control: The cable assembly mounted to the
pump should not be modified in any way except for shortening to a
specific application. Any splice between the pump and the control
panel must be in accordance with all applicable electrical standards.
Gate Valve
½” Pressure
Relief piping
Check Valve
Control Panel
Discharge pipe
Rail guide
Elbow
Float controls