background image

7

0E-TELBSET

 

DESCRIPTION

The Telephone Test Set  is illustrated in Figure 1.

Figure 1.

Metal

Spring-Loaded 

Belt Clip

Mute Button

Graphical

LCD Screen

Microphone

Keypad

Receiver

TELEPHONE TEST SET

0E-TELBSET

Loud

Speaker

Battery

Door

Talk, Bell,

Monitor Buttons

Содержание 0E-TELBSET

Страница 1: ...cord set Large backlit LCD Glow in the dark keypad On hook voltage and off hook current readings Caller ID Call Waiting Caller ID and error detection Last number called or received list Amplified line...

Страница 2: ...4 Automatic Power Down 14 POTS General Guidelines 15 Operation Notes 15 Talk Bell Monitor 15 Talk Setting Talk Mode 16 Off Hook Protection Data Defender 16 Call Waiting Caller ID 17 Speed Dial 17 Flas...

Страница 3: ...t set for use by installers and repair technicians Its state of the art design makes it rugged and water resistant The 0E TELBSET is ideal for temporary communication and servicing and installing tele...

Страница 4: ...switching equipment from push button telephones Tone Tone dialing mode uses the DTMF method to signal the switching equipment for each numbered button press Pulse Pulse dialing mode signals the centr...

Страница 5: ...n the cable is unsafe and exceeds 65 volts peak AC or DC Safety Information To ensure safe operation of the 0E TELBSET follow the instructions carefully and observe the warning and caution messages li...

Страница 6: ...ft key menu system simplifies user interface and customization Contact list of up to 8 names and phone numbers Supports three languages English Spanish and French Measures and displays ring frequency...

Страница 7: ...Telephone Test Set is illustrated in Figure 1 Figure 1 Metal Spring Loaded Belt Clip Mute Button Graphical LCD Screen Microphone Keypad Receiver TELEPHONE TEST SET 0E TELBSET Loud Speaker Battery Doo...

Страница 8: ...ve graphical LCD display screen shown in Figure 3 below The LCD display screen shows the following modes and related icons memory and battery life indicator Angled Bed of Nails with Piercing Clip Cord...

Страница 9: ...t the 0E TELBSET is operating in Talk Mode Tone Pulse Icon Displays whether the 0E TELBSET is in DTMF tone or pulse dial mode Speaker Icon Appears when the loudspeaker is active Microphone Icon Indica...

Страница 10: ...7 8 The unit has eight memory storage locations The slot number is reverse video if in use Memory Dial Each memory slot has the option to view or enter a name and number Memory Name Up to 16 characte...

Страница 11: ...mediately from the source of voltage to prevent damage Figure 4 2 The high current warning is displayed if the current on the line exceeds 125mA If this screen appears the 0E TELBSET should be disconn...

Страница 12: ...nitor or Talk modes The Up Left Down Right buttons are used to scroll through menu options or adjust the volume The speaker button activates the Tel Scope s loudspeaker The twelve digit telephone keyp...

Страница 13: ...e F1 F2 F3 F1 F2 and F3 correspond to the options displayed on the LCD screen directly above them Up Left Down Right Arrows In Talk and Monitor mode these buttons are used to adjust the volume In the...

Страница 14: ...f Press the Bell mode button to power off the 0E TELBSET The OE TELBSET screen will be displayed for 10 seconds before unit is fully powered off Automatic Power Down The 0E TELBSET has automatic power...

Страница 15: ...e angled bed of nails with piercing pin cord set to tip and ring When testing from an RJ11 use an appropriate modular adaptor banjo Important Safety Points to Note xx Volts DISCONNECT NOW message appe...

Страница 16: ...e powered it won t work if there s insufficient power on the line The 0E TELBSET also checks for line voltage exceeding 65 volts If it finds the line voltage exceeds this level it doesn t go off hook...

Страница 17: ...already in progress an incoming call s ID is displayed on the screen During this the label CWCID replaces the line current field The user can switch to the incoming call by pressing the Talk button to...

Страница 18: ...2 seconds the mike will be muted only while the button is held down as soon as you let go it will resume operating normally When the test set is off hook in the TALK mode with the loudspeaker ON the...

Страница 19: ...reen In Bell Mode if the 0E TELBSET is not taken off hook while it is ringing it will power OFF again about 10 seconds after the end of ringing The MON Setting MONITOR Mode Figure 8 MonitormodeScreen...

Страница 20: ...Setup Menu the phone must be in talk or monitor mode not Off Hook Protection mode By pressing the Setup key the 0E TELBSET will present a list of options that can be modified The 0E TELBSET command ke...

Страница 21: ...keys to cancel F1 or save F3 the edited results If you do not want to change the existing name just press F3 to proceed to number entry Once you save the slot s name you then enter the associated pho...

Страница 22: ...iting Use the function keys to Cancel Clear or Save the edited format Ring Volume The Ring volume can be adjusted by pressing F1 decrease audible ring relative to the and F3 increase The 0E TELBSET wi...

Страница 23: ...batteries into the battery cartridge according to the diagram imprinted on the bottom of the battery compartment 5 Return the battery door to the unit and tighten the screw to secure the battery door...

Страница 24: ...be removed if the unit is stored for a long period of time Do not expose the 0E TELBSET to high temperatures or humidity When stored in temperatures exceeding the limits listed in the Specifications s...

Страница 25: ...f purchase All products deemed defective under this warranty will be repaired or replaced at W Box s discretion No further warranties either implied or expressed will apply nor will responsibility for...

Страница 26: ...igh volume with the backlight at 100 on a line with high audio Operating Environment Operating temperature 0 to 50 C 32 to 122 F Storage temperature 20 to 60 C 4 to 140 F Humidity 10 to 90 non condens...

Страница 27: ...digits with 16 charac ter tag stored in non volatile memory Last number redial plus list of last 10 numbers dialed or received Return Loss Minimum 14 dB at 600 Ohms Line Current Range 10 to 110 mA App...

Страница 28: ...UM 0E TELBSET Rev A 0321...

Отзывы: