Shenzhen Waytronic Electronics Co., Ltd
MicroSound M14
https://www.waytronicmfg.com/
3
4.2 Installation method
1) Can hung on the bracket or flat screw through a mounting hole on the back.
2) Can use binding tape to fix it on the column through the middle of hole at the back.
3) Can use double-sided adhesive tape or glue to stick on the wall or other flat surface.
5. Button function introduction
Button A:
l
After switch on, short press is to play, press again to stop.
l
Long press 2s, start to record when hearing a “di” sound; release button and stop recording hearing a “di-di”
sound.
Button B:
l
Short press to play next audio.
l
Short press twice, adjust volume(3 levels in circle, in highest volume, you will hear a "di" sound)
6. Audio download
It’s easy to replace audio files. Just use USB cable to connect to computer, here will appear a drive. You just need
to copy audio files into this drive.
★
Note:
1. The audio file size should be not more than internal FLASH capacity. Only support MP3 audio format.
2. After copying is complete, sometimes play a section voice. When finishing the voice play, 3 seconds later, it
can trigger and play again.
You can copy any voice, tones, music, into this product, as long as the format is MP3, within memory capacity.
Besides, you can make your own personalized voice.
7. Induction triggering
After switch on and finishing recording, after initial power up, 10~25S later it can trigger to play. After playing for
3s, it will trigger again.
8. FAQ
Problem
Solution
Cannot trigger sound after power on
There is an initialization time of about 5 seconds after power-on, and it
can be played only after the initialization is completed.
Battery life is short
You can only choose one of the two using batteries and adapters, not
at the same time.
There is no voice playback when
people continuously passing by
It takes 3 seconds to complete the playback of the previous voice.
It will be played when no one passes
by
1: The product sensor is sensitive to temperature and will trigger
playback when the temperature in the area changes suddenly.
2: The temperature decreases and the sensing distance is
appropriately increased by about 1-2 meters. Please adjust the
installation angle according to actual use.