background image

                       

Shenzhen Waytronic Electronics Co., Ltd

                           

KingSound V2.03

 

 

4

 

 

Note: 

          1. When voice length is more than relay off-delay time, if the time is up, relay will switch off and voice will 
keep playing until finishing its play. 
          2. With power on, about one minutes later, it can play voice normally. In the process of powering up, do not 
align the probe with the heat source or human body, that is, when the red light is off, it can be used normally 

3. In the state of close, relay will switch off with key pressed. 
4. Direction recognition must be from the side of the induction range to the 

other  side,  and  must  be  outside  of  the  induction range.  Just  moving  within  the 
induction range all the time will cause inaccurate direction recognition. Distance 
to identify the direction is within 5 meters; over 5 meters there will be no direction 
recognition or in the opposite direction. 

 

7. 

Downloading voice 

A.

 Copy MP3 format audio files to the root directory of U disk(only voice can be stored in U disk, no any other file). 

If there are special requirements, users need to copy file to the U disk one by one. 

B. 

Send Config.txt to U disk. How to create Config.txt: 

First, create a new notepad on the computer, changing the file-name to Config. Open this file and set as below: 

sp00: sp are small English letters, which means no play with power up. Behind “//”must be reserved.   

cl00: cl are small English letters, which means no loop play. Behind “//”must be reserved.   

cf : cf are small English letters, which are the relay off-delay setting marks. Behind “//”does not need to be 

reserved. 

 

 

 

 

 

 

 

Then, save files and close it after finishing settings.     

C.

 Insert U disk to the host USB interface. 

D. 

Long press both M1 and M2 button for 3 seconds at the same time. When red LED indicator flashes, start to 

copy voice. 

After finishing the copy, the red light stops flashing. 

 

 

They  are  the  relay  closure  time.  The  first  “10”  means  that  closure  time  is  10 

seconds; the second “10” means checking again. This two kinds of time must be 

the  same.  Behind  English  letters,  there  must  be  blank  between  each  two 

numbers. Off-delay time is 00s-99s. 

This byte is interval time between the two body induction triggering. 06 means 

that it takes 6 seconds from finishing voice play to triggering play again, 

triggering interval time is 05-99S. 

00: means that outside triggering play is the audio selected by VOL+ button   

01: means that outside triggering play is the audio selected by VOL- button 

Содержание KingSound

Страница 1: ...ge With the function of direction recognition switching modes freely between no direction recognition and direction recognition Voltage DC12V The off delay time of relay can be set through config txt file 0s 99s 2 Application This product is a smart human body induction voice prompter device with direction recognition external device control external input control function It can be used in the ex...

Страница 2: ...fective COM and NC are external equipment control port will close when body induction triggers to play 5 FLASH capacity and voice length This version supports 8 320Kbps MP3 audio file voice length is related to the bit rate The lower the rate is the smaller the file is Note that the total size of the voice file cannot be greater than the capacity of the internal FLASH If the internal FLASH memory ...

Страница 3: ...olume 8th level is the max Replay the current track Green light on Next VOL Short press not adjusting volume Selection of playing voice from left to right Green light on Switch to the next Green light on Long press 3S Into adjusting volume mode Red light flashes at 2HZ Into adjusting volume mode Red light flashes at 2HZ Short press adjusting volume Decrease one level volume Replay the current trac...

Страница 4: ...to U disk How to create Config txt First create a new notepad on the computer changing the file name to Config Open this file and set as below sp00 sp are small English letters which means no play with power up Behind must be reserved cl00 cl are small English letters which means no loop play Behind must be reserved cf cf are small English letters which are the relay off delay setting marks Behind...

Страница 5: ...e rated power d Do not install in the place with temperature over 40 and large air flow or great temperature variation Indemnification SHENZHEN WAYTRONIC ELECTRONIC CO LTD reserves the right to modify and use information without prior notice to customers New product specifications will be subject to the latest version Contact Us Shenzhen Waytronic Electronics Co Ltd Tel 86 755 29605099 Fax 86 755 ...