Shenzhen Waytronic Electronics Co., Ltd
KingSound V2.03
3
6.
Operation instructions
6.1 Key-press operation
Key
Operation
Direction recognition mode
No direction recognition mode
Function
Indicator
Function
Indicator
M1
Short press
None
Red light on for 2
seconds
Switch to A
mode(all cycle)
Red light on for 2
seconds
Long press 3S
None
None
None
None
M2
Short press
None
Red light on for 2
seconds
Switch to B
mode(single
cycle)
Red light on for 2
seconds
Long press 3S
Switch to no
direction recognition
mode
Red light flashes
4 times
Switch to direction
recognition mode
Red light flashes 2
times
Previou
s
VOL+
Short press(not
adjusting
volume)
Selection of playing
voice from left to
right.
Green light on
Switch to the
previous audio
Green light on
Long press 3S
Into adjusting
volume mode
Red light flashes
at 2HZ
Into adjusting
volume mode
Red light flashes at
2HZ
Short
press(adjusting
volume)
Increase one-level
volume. 8 level is
the maximum.
Replay the current
track.
Green light on
Increase one-level
volume. 8th level
is the max. Replay
the current track.
Green light on
Next
VOL-
Short press
(
not adjusting
volume
)
Selection of playing
voice from left to
right.
Green light on
Switch to the next
Green light on
Long press 3S
Into adjusting
volume mode
Red light flashes
at 2HZ
Into adjusting
volume mode
Red light flashes at
2HZ
Short press
(
adjusting
volume
)
Decrease one-level
volume. Replay the
current track.
Green light on
Decrease
one-level volume.
Replay the current
track.
Green light on
6.2 Human body induction trigger
The human body induction is triggered only when there is no any other operations. When the human body
induction is triggered, open the relay, and start timing its delay time. In the process of playing, green LED indicator
light is on all the time; after finishing playing, light off. After ending the voice play, if it is not the relay off-delay time,
the relay will be still closed. Within the relay closure time, red LED indicator flashes with 2-second cycle. If there is
voice triggering within the relay off-delay time, the time will be cleared, and red LED is no longer flashing; relay
still keeps working. Besides, the relay is switched off without triggering operation within the relay off-delay time.