INSTALLATION MANUAL

7

TROUBLESHOOTING

Symptoms

Possible Cause(s)

Suggested Remedies

Pump will not  
start or run 
 
 
 
 
 
 

1. Water level too low
2. Blown fuse or tripped circuit breaker 

3. Low supply voltage
4. Motor
5. Switch
6. Inlet clogged
7. Switch obstruction

1. Water must be at the appropriate level to activate switch 
2. If blown, determine cause and then either replace with proper 

sized fuse or reset breaker

3. Contact an electrician
4. Replace pump
5. Replace switch
6. Remove debris
7. Remove obstruction to verify free motion of switch

Pump starts and 
stops too often

1. Back-flow of water from discharge 

pipe

2. Switch
3. Check valve not functioning properly 

or leaking

1. Install check valve 

2. Replace switch
3. Remove and examine check valve for prop er in stal la tion and free 

operation. Replace check valve if necessary.

Pump shuts off 
and turns on 
independently 
of switch (trips 
thermal overload 
protection)

1. Switch
2. Switch obstruction
3. Obstruction in discharge pipe
4. Low supply voltage

1. Replace tether switch
2. Remove obstruction to verify free motion of switch
3. Remove obstruction in discharge piping
4. Contact an electrician.

TROUBLESHOOTING WARNINGS

ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY 

before 

installing, servicing or making any adjustments.

TOUJOURS METTRE LA POMPE HORS TENSION 

avant de procéder à 

l’installation, à l’entretien ou à des réglages.

LET PUMP COOL FOR A MINIMUM OF 2 HOURS BEFORE ATTEMPTING TO 

SERVICE. 

Submersible pumps contain oil that become pressurized 

and hot under normal operating conditions. 

LAISSER REFROIDIR LA POMPE PENDANT AU MOINS 2 HEURES AVANT 

D’ESSAYER DE LA RÉPARER. 

Les pompes submersibles contiennent 

de l’huile qui devient pressurisée et chaude dans des conditions 

normales de fonctionnement.

1.  Submersible pump models have permanently lubricated 

bearings and require no additional lubrication.

2.  Submersible pumps contain dielectric oil for cooling.  

Dielectric oil can be harmful to the environment.  Follow 
state environmental laws when disposing of oil.

3.  The pump motor is equipped with automatic resetting 

thermal protector and may restart unexpectedly.  Protector 
tripping is an indication of motor overloading as a result of 
operating the pump at low heads, excessively high or low 
voltage, inadequate wiring, incorrect motor conditions, or at 
the end of its life.

Содержание RPP50

Страница 1: ...Reinforced Thermoplastic SEL50 EFL50 Glass Reinforced Thermoplastic IMPELLER Glass Reinforced Thermoplastic SHAFT Steel DISCHARGE 2 in NPT Sewage Effluent Pumps PERFORMANCE Model HP Discharge Head 0 f...

Страница 2: ...ire le risque de choc lectrique s assurer qu elle est branch e seulement une prise de courant correctement mise la terre FOR ADDED SAFETY the receptacle must be protected with a ground fault circuit i...

Страница 3: ...ACHEMINEMENT D EAU DESTIN E LA CONSOMMATION Ne pas utiliser la pompe pour transporter de l eau qui sera utilis e comme de l eau potable destin e la consommation La pompe doit tre utilis e uniquement...

Страница 4: ...PUMP SHOULD BE USED when risk of property damage from high water levels exists UNE ALARME AUTONOME DE NIVEAU D EAU LEV OU UNE POMPE DE SAUVEGARDE DOIVENT TRE UTILIS ES en cas de risque de d g ts mat...

Страница 5: ...tructions 6 Install discharge plumbing according to local regional and state codes Do not reduce the discharge pipe size below that which is provided on the pump 7 If optional control device or float...

Страница 6: ...uld be installed above the check valve as required by local regional or state codes 10 Connect remaining discharge pipe The remainder of the discharge line should be as short as possible with a minimu...

Страница 7: ...n of switch 3 Remove obstruction in discharge piping 4 Contact an electrician TROUBLESHOOTING WARNINGS ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY before installing servicing or making any adjustment...

Страница 8: ...p 4 Recheck all sizing calculations to determine proper pump size 5 Remove and examine check valve for proper installation and free operation 6 Open valve ROUTINE MAINTENANCE The pump should be inspec...

Страница 9: ...RRANTY SERVICE PARTS SHEET REPLACEMENT PARTS REPAIR KITS REF NO DESCRIPTION MODELS Sewage RPP50 SEL50 WCS50T Effluent EFL50 1 TETHER SWITCH ALL MODELS 56835 WYN1 2 10 FT CORD WCS50T ONLY 31006 WYN2 9...

Страница 10: ...s Limited Warranty does not cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with Wayn...

Страница 11: ..._____________________________________________________________________________________________ _____________________________________________________________________________________________ ___________...

Страница 12: ...12 www waynepumps com...

Отзывы: