background image

INSTALLATION MANUAL

2

SAFETY SIGNAL WORDS

This manual contains information that is very important 
to know and understand. This information is provided for 
SAFETY and to PREVENT EQUIPMENT PROBLEMS. To 
help recognize this information, observe all safety information 
labeled danger, warning, caution, and notice. 

SEWAGE/EFFLUENT PUMP 

DESCRIPTION

Sewage pumps are pumps used to remove waster water that 

contains solids up to 2 inches in diameter. The most common 

application is for draining bathroom waster water to a sewer or 

septic line.

Effluent pumps are pumps used to remove gray water from 

septic tanks, sump pits, or laundry tray systems. Gray water is 

waste water from bathtubs, sinks, washing machines, and other 

kitchen appliances.

UNPACKING

Inspect this unit before it is used. Occasionally, products are damaged 
during shipment. If the pump or components are damaged, return 
the unit to the place of purchase for replacement, or call Customer 
Support (800-237-0987).

Intended for Indoor Use Only

PLEASE SEE WWW.WAYNEPUMPS.COM FOR PRODUCT INFORMATION AND INSTALLATION VIDEOS

MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE 

AVAILABLE. 

This pump is supplied with a grounding conductor 

and grounding-type attachment plug. To reduce the risk of electric 

shock, be certain that it is connected only to a properly grounded, 

grounding-type receptacle.

S’ASSURER QU’UNE PRISE DE MISE À LA TERRE EST DISPONIBLE. 

Cette pompe est fournie avec un conducteur et une fiche de mise à 

la terre. Pour réduire le risque de choc électrique, s’assurer qu’elle 

est branchée seulement à une prise de courant correctement mise 

à la terre.

FOR ADDED SAFETY 

the receptacle must be protected with a ground 

fault circuit interrupter (GFCI). All wiring must be performed by a 

qualified licensed electrician and comply with the National Electric 

Code and all applicable local codes and ordinances.

POUR PLUS DE SÉCURITÉ, 

la prise de courant doit être protégée par 

un disjoncteur de fuite à la terre. Tout le câblage doit être effectué 

par un électricien qualifié et être conforme au Code électrique 

national et à tous les codes et règlements locaux applicables.

NEVER REMOVE THE GROUND PRONG 

from the plug or bypass the 

grounding wires.

NE JAMAIS RETIRER LE CONNECTEUR DE MISE À LA TERRE 

de la prise 

ou contourner les fils de mise à la terre.

MAKE SURE THE POWER SUPPLY HAS A FUSE OR CIRCUIT BREAKER 

rated to handle the current (amps) noted on the pump nameplate 

or cordtag.

S’ASSURER QUE L’ALIMENTATION ÉLECTRIQUE EST MUNIE D’UN 

FUSIBLE OU D’UN DISJONCTEUR 

d’une valeur nominale appropriée 

pour supporter l’intensité du courant (ampérage) indiquée sur la 

plaque signalétique ou l’étiquette du cordon de la pompe.

IMPORTANT SAFETY INFORMATION
CONSIGNES DE SÉCURITÉ 

IMPORTANTES

WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION 

WHICH, IF NOT AVOIDED, COULD RESULT IN DEATH OR 

SERIOUS INJURY.

LA MENTION AVERTISSEMENT INDIQUE UNE SITUATION 

POTENTIELLEMENT DANGEREUSE QUI, SI ELLE N’EST PAS 

ÉVITÉE, RISQUE D’ENTRAÎNER DES LÉSIONS CORPORELLES 

GRAVES OU MÊME LA MORT.

RISK OF ELECTRIC SHOCK. TO REDUCE THIS RISK, 

OBSERVE THE FOLLOWING WARNINGS:
RISQUE DE CHOC ÉLECTRIQUE. POUR RÉDUIRE CE 

RISQUE, TENIR COMPTE DES AVERTISSEMENTS 

SUIVANTS 

Содержание EFL50

Страница 1: ... Reinforced Thermoplastic SEL50 EFL50 Glass Reinforced Thermoplastic IMPELLER Glass Reinforced Thermoplastic SHAFT Steel DISCHARGE 2 in NPT Sewage Effluent Pumps PERFORMANCE Model HP Discharge Head 0 ft 5 ft 10 ft 15 ft 20 ft RPP50 1 2 Gal hr 6200 4800 3240 1500 SEL50 1 2 Gal hr 10000 9000 7200 5000 2000 WCS50T 1 2 Gal hr 10000 9600 8000 3300 EFL50 1 2 Gal hr 10000 9000 7200 5000 2000 Intended for...

Страница 2: ...que de choc électrique s assurer qu elle est branchée seulement à une prise de courant correctement mise à la terre FOR ADDED SAFETY the receptacle must be protected with a ground fault circuit interrupter GFCI All wiring must be performed by a qualified licensed electrician and comply with the National Electric Code and all applicable local codes and ordinances POUR PLUS DE SÉCURITÉ la prise de c...

Страница 3: ...ACHEMINEMENT D EAU DESTINÉE À LA CONSOMMATION Ne pas utiliser la pompe pour transporter de l eau qui sera utilisée comme de l eau potable destinée à la consommation La pompe doit être utilisée uniquement dans les applications pour lesquelles elle est conçue DO NOT USE AN EXTENSION CORD OR SURGE PROTECTOR Extension cords and or surge protectors could present a safety hazard if not sized properly be...

Страница 4: ...P SHOULD BE USED when risk of property damage from high water levels exists UNE ALARME AUTONOME DE NIVEAU D EAU ÉLEVÉ OU UNE POMPE DE SAUVEGARDE DOIVENT ÊTRE UTILISÉES en cas de risque de dégâts matériels causés par des niveaux d eau élevés REPLACE THE SWTICH EVERY T WO 2 YEARS This maintenance will reduce the risk of improper pump operation switch failure and or flooding REMPLACER LE COMMUTATEUR ...

Страница 5: ...structions 6 Install discharge plumbing according to local regional and state codes Do not reduce the discharge pipe size below that which is provided on the pump 7 If optional control device or float is used follow mounting instruction supplied with device or float 8 A union should be installed above the basin to allow easy removal of the pump for cleaning and service 9 Install a check valve requ...

Страница 6: ...ould be installed above the check valve as required by local regional or state codes 10 Connect remaining discharge pipe The remainder of the discharge line should be as short as possible with a minimum number of turns 11 Secure power supply cord to discharge pipe using cable or zip ties to prevent possible switch entanglement 12 Connect pump power supply cord to a ground fault circuit interrupter...

Страница 7: ...of switch 3 Remove obstruction in discharge piping 4 Contact an electrician TROUBLESHOOTING WARNINGS ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY before installing servicing or making any adjustments TOUJOURS METTRE LA POMPE HORS TENSION avant de procéder à l installation à l entretien ou à des réglages LET PUMP COOL FOR A MINIMUM OF 2 HOURS BEFORE ATTEMPTING TO SERVICE Submersible pumps contain o...

Страница 8: ...mp 4 Recheck all sizing calculations to determine proper pump size 5 Remove and examine check valve for proper installation and free operation 6 Open valve ROUTINE MAINTENANCE The pump should be inspected 3 4 times per year for pump movement or buildup of debris on the switch or floar Reposition pump if it has moved Remove any debris that could interfere with the operation of the switch Lack of pr...

Страница 9: ...ARRANTY SERVICE PARTS SHEET REPLACEMENT PARTS REPAIR KITS REF NO DESCRIPTION MODELS Sewage RPP50 SEL50 WCS50T Effluent EFL50 1 TETHER SWITCH ALL MODELS 56835 WYN1 2 10 FT CORD WCS50T ONLY 31006 WYN2 9 2 ...

Страница 10: ...is Limited Warranty does not cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with Wayne Water Systems written instructions THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES OBLIGATIONS OR AGREEMENTS EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNE...

Страница 11: ..._ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ ______________________...

Страница 12: ...12 www waynepumps com ...

Отзывы: